F71872  
7
IRQ_MODE  
R
R
0
0: interrupt is ISA pulse.  
1: interrupt is ISA level.  
Only valid in ECP and ECP_MODE is 111b.  
6-4 IMPID  
001 000: the design is 16-bit implementation.  
001: the design is 8-bit implementation (default).  
010: the design is 32-bit implementation.  
011-111: Reserved.  
Only valid in ECP and ECP_MODE is 111b.  
3
2
Reserved  
BYTETRAN_N  
-
-
Reserved.  
R
1
0: when transmitting there is 1 byte waiting in the transceiver that does not  
affect the FIFO full condition.  
1: when transmitting the state of the full bit includes the byte being transmitted.  
Only valid in ECP and ECP_MODE is 111b.  
1-0 Reserved  
R
00  
Return 00 when read.  
Only valid in ECP and ECP_MODE is 111b.  
7.5.3.11 ECP Configuration Register B Base + 401h  
Bit  
Name  
R/W Default  
Description  
7
COMP  
R
0
1
0: only send uncompressed data.  
1: compress data before sending.  
Only valid in ECP and ECP_MODE is 111b.  
6
Reserved  
R
R
Reserved. Return 1 when read.  
Only valid in ECP and ECP_MODE is 111b.  
5-3 ECP_IRQ_CH  
001 000: the interrupt selected with jumper.  
001: select IRQ 7 (default).  
010: select IRQ 9.  
011: select IRQ 10.  
100: select IRQ 11.  
101: select IRQ 14.  
110: select IRQ 15.  
111: select IRQ 5.  
Only valid in ECP and ECP_MODE is 111b.  
2-0 ECP_DMA_CH  
R
011 Return the DMA channel of ECP parallel port.  
Only valid in ECP and ECP_MODE is 111b.  
7.5.3.12 Extended Control Register Base + 402h  
Bit  
Name  
R/W Default  
Description  
66  
July, 2007  
V0.28P  