F71862  
C5h  
R/W  
8’hff  
FAN3 full speed count reading (LSB).  
VT3 BOUNDARY 1 TEMPERATURE – Index C6h  
Bit  
Name  
R/W Default  
Description  
Return 0 when read.  
7
Reserved  
RO  
0
The 1st BOUNDARY temperature for VT3 in temperature mode.  
When VT3 temperature is exceed this boundary, FAN3 expect value will  
load the full speed duty 8’hFF.  
3Ch  
(60oC)  
6-0  
BOUND1TMP3  
R/W  
When VT3 temperature is below this boundary – hysteresis, FAN3 expect  
value will load from segment 1 register (index CBh).  
VT3 BOUNDARY 2 TEMPERATURE – Index C9  
Bit  
Name  
R/W Default  
Description  
Return 0 when read.  
7
Reserved  
RO  
0
The 2st BOUNDARY temperature for VT3 in temperature mode.  
When VT3 temperature is exceed this boundary, FAN3 expect value will  
load from segment 1 register (index CBh).  
1Eh  
(30oC)  
6-0  
BOUND2TMP3  
R/W  
When VT3 temperature is below this boundary – hysteresis, FAN3 expect  
value will load from segment 2 register (index CEh).  
FAN3 SEGMENT 1 SPEED COUNT – Index CBh  
Bit  
Name  
R/W Default  
Description  
The value that set in this byte is mean the expect PWM duty-cycle in this  
temperature section.  
D9h  
R/W  
7-0  
SEC1SPEED3  
(85%)  
FAN3 SEGMENT 2 SPEED COUNT  
– Index CEh  
Bit  
Name  
R/W Default  
Description  
The value that set in this byte is mean the expect PWM duty-cycle in this  
temperature section.  
80h  
R/W  
7-0  
SEC2SPEED3  
(50%)  
FAN3 Temperature Mapping Select – Index CFh  
Bit  
7-6  
5
Name  
Reserved  
R/W Default  
Description  
Reserved  
--  
0
0
0
Set 1 to force FAN3 to full speed if any temperature over its high limit.  
Set 1 will enable the interpolation of the fan expect table.  
FAN3_UP_T_EN  
FAN3_INTERPOLATION_  
EN  
R/W  
4
R/W  
This register controls the FAN3 duty movement when temperature over  
highest boundary.  
0: The FAN3 duty will increases with the slope selected by  
FAN3_RATE_SEL register (Index 9Bh).  
1: The FAN3 duty will directly jumps to full speed.  
This register controls the FAN3 duty movement when temperature under  
(highest boundary – hysteresis).  
0: The FAN3 duty will decreases with the slope selected by  
FAN3_RATE_SEL register (Index 9Bh).  
1
3
FAN3_JUMP_HIGH_EN R/W  
FAN3_JUMP_LOW_EN R/W  
1
2
1: The FAN3 duty will directly jumps to the value of SEC1SPEED3  
register.  
62  
July, 2008  
V.28P  