 浏览型号F71862FG的Datasheet PDF文件第57页浏览型号F71862FG的Datasheet PDF文件第58页浏览型号F71862FG的Datasheet PDF文件第59页浏览型号F71862FG的Datasheet PDF文件第60页浏览型号F71862FG的Datasheet PDF文件第62页浏览型号F71862FG的Datasheet PDF文件第63页浏览型号F71862FG的Datasheet PDF文件第64页浏览型号F71862FG的Datasheet PDF文件第65页  
F71862  
FAN2 SEGMENT 1 SPEED COUNT – Index BBh  
Bit  
Name  
R/W Default  
Description  
The value that set in this byte is mean the expect PWM duty-cycle in this  
temperature section.  
D9h  
R/W  
7-0  
SEC1SPEED2  
(85%)  
FAN2 SEGMENT 2 SPEED COUNT  
– Index BEh  
Bit  
Name  
R/W Default  
Description  
The value that set in this byte is mean the expect PWM duty-cycle in this  
temperature section.  
80h  
R/W  
7-0  
SEC2SPEED2  
(50%)  
FAN2 Temperature Mapping Select – Index BFh  
Bit  
7-6  
5
Name  
Reserved  
R/W Default  
Description  
Reserved  
--  
0
0
0
Set 1 to force FAN2 to full speed if any temperature over its high limit.  
Set 1 will enable the interpolation of the fan expect table.  
FAN2_UP_T_EN  
FAN2_INTERPOLATION_  
EN  
R/W  
4
R/W  
This register controls the FAN2 duty movement when temperature over  
highest boundary.  
0: The FAN2 duty will increases with the slope selected by  
FAN2_RATE_SEL register (Index 9Bh).  
1: The FAN2 duty will directly jumps to full speed.  
This register controls the FAN2 duty movement when temperature under  
(highest boundary – hysteresis).  
0: The FAN2 duty will decreases with the slope selected by  
FAN2_RATE_SEL register (Index 9Bh).  
1: The FAN2 duty will directly jumps to the value of SEC1SPEED2  
register.  
1
3
FAN2_JUMP_HIGH_EN R/W  
FAN2_JUMP_LOW_EN R/W  
1
2
0: reserved.  
1: fan2 follow temperature 1.  
1-0  
Fan2_temp_sel  
R/W  
2h  
2: fan2 follow temperature 2.  
3: fan2 follow temperature 3.  
Fan3 Index C0h- CFh  
Default  
Value  
Address  
Attribute  
Description  
FAN3 count reading (MSB). At the moment of reading this register, the LSB will  
be latched. This will prevent from data updating when reading. To read the fan  
count correctly, read MSB first and followed read the LSB.  
C0h  
RO  
8’h0F  
C1h  
C2h  
RO  
-
8’hff  
-
FAN3 count reading (LSB).  
Reserved.  
The Value programming in this byte is duty value. In auto fan mode(CR96  
bit5Î0) this register is updated by hardware.  
Ex: 5Î 5*100/255 %  
C3h  
C4h  
R/W  
R/W  
8’h01  
8’h03  
255 Î 100%  
FAN3 full speed count reading (MSB). At the moment of reading this register,  
the LSB will be latched. This will prevent from data updating when reading. To  
read the fan count correctly, read MSB first and followed read the LSB.  
61  
July, 2008  
V.28P  