F71869A
This register controls the FAN2 duty movement when temperature
under (highest boundary – hysteresis).
0: The FAN2 duty will decreases with the slope selected by
FAN2_RATE_SEL register.
FAN2_JUMP_
LOW_EN
2
R/W
1
1: The FAN2 duty will directly jumps to the value of SEC2SPEED2
register.
This bit only activates in duty mode.
This registers companying with FAN2_TEMP_SEL_DIG select the
temperature source for controlling FAN2. The following value is
comprised by {FAN2_TEMP_SEL_DIG, FAN2_TEMP_SEL}
000: fan2 follows PECI temperature (CR7Eh)
001: fan2 follows temperature 1 (CR72h).
010: fan2 follows temperature 2 (CR74h).
1-0
FAN2_TEMP_SEL R/W
10
011: fan2 follows temperature 3 (CR76h).
100: fan2 follows IBEX/TSI CPU temperature (CR7Ah)
101: fan2 follows IBEX PCH temperature (CR7Bh).
110: fan2 follows IBEX MCH temperature (CR7Ch).
111: fan2 follows IBEX maximum temperature (CR7Dh).
Otherwise: reserved.
6.6.87 FAN3 Index C0h- CFh
Address Attribute Default Value
Description
FAN3 count reading (MSB). At the moment of reading this register,
the LSB will be latched. This will prevent from data updating when
reading. To read the fan count correctly, read MSB first and followed
read the LSB.
C0h
C1h
RO
RO
8’h0F
8’hff
FAN3 count reading (LSB).
RPM mode(CR96 bit4=0):
FAN3 expect speed count value (MSB), in auto fan mode(CR96
bit5Î0) this register is auto updated by hardware.
Duty mode(CR96 bit4=1):
C2h
C3h
R/W
R/W
8’h00
8’h01
This byte is reserved byte.
RPM mode(CR96 bit4=0):
FAN3 expect speed count value (LSB) or expect PWM duty , in auto
fan mode this register is auto updated by hardware and read only.
Duty mode(CR96 bit4=1):
The Value programming in this byte is duty value. In auto fan
102
Oct., 2011
V0.19P