Absolute Maximum Ratings(Note 3)
Note 3: The “Absolute Maximum Ratings” are those values beyond which
the safety of the device cannot be guaranteed. The device should not be
operated at these limits. The parametric values defined in the Electrical
Characteristics tables are not guaranteed at the absolute maximum ratings.
The “Recommended Operating Conditions” table will define the conditions
for actual device operation.
Supply Voltage
Input Voltage
7V
7V
Operating Free Air Temperature Range
Storage Temperature Range
0°C to +70°C
−65°C to +150°C
Recommended Operating Conditions
Symbol
Parameter
Min
4.75
2
Nom
Max
Units
V
VCC
VIH
VIL
IOH
IOL
TA
Supply Voltage
5
5.25
HIGH Level Input Voltage
LOW Level Input Voltage
HIGH Level Output Current
LOW Level Output Current
Free Air Operating Temperature
V
0.8
−0.4
8
V
mA
mA
°C
0
70
Electrical Characteristics
over recommended operating free air temperature range (unless otherwise noted)
Symbol Parameter Conditions
Input Clamp Voltage = Min, I = −18 mA
Typ
Min
Max
Units
(Note 4)
V
V
V
V
V
V
V
−1.5
V
V
I
CC
CC
I
HIGH Level
= Min, I = Max,
OH
OH
2.7
Output Voltage
LOW Level
= Max
IL
V
= Min, I = Max,
OL
OL
CC
0.35
0.25
0.5
Output Voltage
= Min
V
IH
I
= 4 mA, V = Min
0.4
0.1
OL
CC
I
I
I
Input Current @ Max
Input Voltage
V
= Max, V = 7V
M input
A , B
I
CC
CC
CC
CC
I
0.3
n
n
mA
S
0.4
n
C
0.5
n
HIGH Level
V
V
V
= Max, V = 2.7V
M input
A , B
20
IH
IL
I
Input Current
60
n
n
µA
S
80
n
C
100
−0.4
−1.2
−1.6
−2.0
n
LOW Level
= Max, V = 0.4V
M input
A , B
I
Input Current
n
n
mA
S
n
C
n
I
I
Short Circuit
= Max
OS
CC
−20
−100
mA
mA
Output Current
(Note 5)
V = Max, B , C = GND
CC
Supply Current
n
n
37
S , M, A = 4.5V
n
n
Note 4: All typicals are at V = 5V, T = 25°C.
CC
A
Note 5: Not more than one output should be shorted at a time, and the duration should not exceed one second.
www.fairchildsemi.com
4