E S I
E S I
ADVANCED INFORMATION
Command Definitions
Excel Semiconductor inc.
Table 9. ES29DL320 Command Definitions
Bus Cycles (Notes 2~5)
Fourth
Command
Sequence
(Note 1)
First
Addr
RA
Second
Addr
Third
Addr
Fifth
Sixth
Data
RD
F0
Data
Data
Addr
Data
Addr
Data
Addr
Data
Read (Note 6)
Reset (Note 7)
1
1
XXX
555
Word
Byte
Word
Byte
Word
Byte
Word
Byte
Word
Byte
Word
Byte
Word
Byte
Word
Byte
2AA
555
2AA
555
2AA
555
2AA
555
2AA
555
2AA
555
2AA
555
2AA
555
PA
(BA)555
(BA)AAA
(BA)555
(BA)AAA
(BA)555
(BA)AAA
(BA)555
(BA)AAA
555
Manufacturer ID
Device ID
4
4
4
4
3
4
4
3
AA
AA
AA
AA
AA
AA
AA
AA
55
55
55
55
55
55
55
55
90
90
90
90
88
90
A0
20
(BA)X00
4A
AAA
555
(BA)X01
(BA)X02
(BA)X03
(BA)X06
(SA)X02
(SA)X04
41/81
82/02
00/01
AAA
555
Security Sector Fac
tory Protect (Note10)
AAA
555
Sector Protect Verify
(Note 11)
AAA
555
Enter Security Sector Region
Exit Security Sector Region
Program
AAA
555
AAA
555
XXX
PA
00
AAA
555
AAA
555
PD
AAA
555
AAA
555
Unlock Bypass
AAA
XXX
XXX
555
AAA
Unlock Bypass Program (Note 12)
Unlock Bypass Reset (Note 13)
2
2
A0
90
PD
00
XXX
2AA
555
2AA
555
Word
Byte
Word
Byte
555
AAA
555
555
AAA
555
2AA
555
2AA
555
555
Chip Erase
6
6
AA
AA
55
55
80
80
AA
AA
55
55
10
30
AAA
555
AAA
Sector Erase
SA
AAA
XXX
XXX
55
AAA
AAA
Erase Suspend (Note 14)
Erase Resume (Note 15)
1
1
B0
30
Word
Byte
CFI Query (Note 16)
1
98
AA
Legend:
PD = Data to be programmed at location PA. Data latches on the
rising edge of WE# or CE# pulse, whichever happens first.
SA = Address of the sector to be verified (in autoselect mode) or
erased. Address bits A20-A12 uniquely select any sector.
BA = Address of the bank that is being switched to autoselect
mode, is in bypass mode, or is being erased.
X = Don’t care
RA = Address of the memory location to be read.
RD = Data read from location RA during read operation
PA = Address of the memory location to be programmed.
Addresses latch on the falling edge of the WE# or CE# pulse,
whichever happens later.
Notes:
9. The device ID is 41h for top boot device, and 81h for bottom
boot device.
10. The data is 82h for factory locked and 02h for not factory
locked.
11. The data is 00h for an unprotected sector and 01h for a
protected sector.
12. The Unlock Bypass command is required prior to the Unlock-
Bypass Program command.
1. See Table 1 for description of bus operations.
2. All values are in hexadecimal.
3. Except for the read cycle and the fourth cycle of the autoselect
command sequence, all bus cycles are write cycles.
4. Data bits DQ15-DQ8 are don’t care in command sequences,
except for RD and PD
5. Unless otherwise noted, address bits A20-A11 are don’t cares.
6. No unlock or command cycles required when bank is in
read mode.
7. The Reset command is required to return to the read mode
(or to the erase-suspend-read mode if previously in Erase
Suspend) when a bank is in the autoselect mode, or if DQ5
goes high (while the bank is providing status information).
8. The fourth cycle of the autoselect command sequence
is a read cycle. The system must provide the bank address
to obtain the manufacturer ID, device ID, or SecSi Sector
factory protect information. Data bits DQ15-DQ8 are
don’t care. See the Autoselect Command Sequence section
for more information.
13. The Unlock Bypass Reset command is required to return
to the read mode when the bank is in the unlock bypass
mode.
14. The system may read and program in non-erasing sectors,
or enter the autoselect mode, when in the Erase Suspend
mode. The Erase Suspend command is valid only during
a sector erase operation, and requires the bank address.
15. The Erase Resume command is valid only during the Erase
Suspend mode, and requires the bank address.
16. Command is valid when device is ready to read array data
or when device is in autoselect mode.
23
Rev. 0E May 25, 2006
ES29DL320