EM63A165
EtronTech
Table 15. D.C. Characteristics
(VDD = 3.3V ± 0.3V, TA = -40~85°C)
-5I
65
30
- 6I
Max.
-7I
Symbol
Unit Note
Description/Test condition
Operating Current
tRC ≥ tRC(min), Outputs Open
One bank active
Precharge Standby Current in non-power down mode
tCK = 15ns, CS# ≥ VIH(min), CKE ≥ VIH
Input signals are changed every 2clks
Precharge Standby Current in non-power down mode
tCK = ∞, CLK ≤ VIL(max), CKE ≥ VIH
60
25
55
20
IDD1
3
IDD2N
18
2
18
2
18
2
IDD2NS
IDD2P
Precharge Standby Current in power down mode
tCK = 15ns, CKE ≤ VIL(max)
Precharge Standby Current in power down mode
tCK = ∞, CKE ≤ VIL(max)
2
2
2
IDD2PS
mA
Active Standby Current in non-power down mode
tCK = 15ns, CKE ≥ VIH(min), CS# ≥ VIH(min)
Input signals are changed every 2clks
Active Standby Current in non-power down mode
CKE ≥ VIH(min), CLK ≤ VIL(max), tCK = ∞
Operating Current (Burst mode)
tCK =tCK(min), Outputs Open, Multi-bank interleave
Refresh Current
tRC ≥ tRC(min)
40
35
30
IDD3N
40
65
80
35
62
75
30
60
70
IDD3NS
IDD4
3, 4
3
IDD5
Self Refresh Current
CKE ≤ 0.2V ; for other inputs VIH VDD - 0.2V, VIL ≤ 0.2V
2
2
2
IDD6
≧
Rev. 2.2
18