Ericsson Internal
E
SECSUND
PRODUCT SPECIFICATION
3 (4)
Prepared (also subject responsible if other)
No.
31/1301-BMR 456+ Uen
42
Technical Specification
BMR456 series Fully regulated AdvCahneckceed d Bus Converters
Approved
Date
Rev
Reference
1/28701-FGC 101 1823 revD February 2013
SEC/D (Julia You)
EMAOLII
2012-06-25
B
© Ericsson AB
Input 36-75 V, Output up to 39 A / 468 W
Designation
Cmd Prot
Notes:
READ_FREQUENCY
95h
No
Cmd, is short for Command.
Prot, is short for commands that are protected with security
mask.
Configuration and Control Commands
USER_DATA_00
B0h
No
Identification Commands (Read Only)
PMBUS_REVISION
MFR_ID
98h
99h
9Ah
9Bh
No
Yes
Yes
Yes
MFR_MODEL
MFR_REVISION
MFR_LOCATION
9Ch Yes
9Dh Yes
MFR_DATE
MFR_SERIAL
9Eh
Yes
Supervisory Commands
STORE_DEFAULT_ALL
RESTORE_DEFAULT_ALL
STORE_USER_ALL
RESTORE_USER_ALL
CAPABILITY
11h
12h
15h
16h
19h
Yes
No
No
No
No
Product Specific Commands
MFR_POWER_GOOD_POLARITY
D0h No
D3h Yes
DCh No
DDh Yes
DEh Yes
MFR_VIN_SCALE_MONITOR
MFR_SELECT_TEMP_SENSOR
MFR_VIN_OFFSET
MFR_VOUT_OFFSET_MONITOR
MFR_TEMP_OFFSET_INT
MFR_REMOTE_TEMP_CAL
MFR_REMOTE_CTRL
E1h
E2h
E3h
No
No
No
MFR_DEAD_BAND_DELAY
MFR_TEMP_COEFF
E5h
E7h
F0h
F1h
F2h
F3h
F4h
F5h
Yes
Yes
No
MFR_DEBUG_BUFF
MFR_SETUP_PASSWORD
MFR_DISABLE_SECURITY_ONCE
MFR_DEAD_BAND_IOUT_THRESHOLD
MFR_SECURITY_BIT_MASK
MFR_PRIMARY_TURN
No
No
Yes
Yes
Yes
MFR_SECONDARY_TURN
MFR_ILIM_SOFTSTART
F6h
F8h
Yes
No
MFR_MULTI_PIN_CONFIG
MFR_DEAD_BAND_VIN_THRESHOLD
MFR_DEAD_BAND_VIN_IOUT_HYS
MFR_RESTART
F9h
No
FAh Yes
FBh Yes
FEh No