 浏览型号BMR4560004/018的Datasheet PDF文件第34页浏览型号BMR4560004/018的Datasheet PDF文件第35页浏览型号BMR4560004/018的Datasheet PDF文件第36页浏览型号BMR4560004/018的Datasheet PDF文件第37页浏览型号BMR4560004/018的Datasheet PDF文件第39页浏览型号BMR4560004/018的Datasheet PDF文件第40页浏览型号BMR4560004/018的Datasheet PDF文件第41页浏览型号BMR4560004/018的Datasheet PDF文件第42页  
E
38  
Technical Specification  
BMR456 series Fully regulated Advanced Bus Converters  
1/28701-FGC 101 1823 revD February 2013  
© Ericsson AB  
Input 36-75 V, Output up to 39 A / 468 W  
Thermal Consideration  
General  
The product is designed to operate in different thermal  
environments and sufficient cooling must be provided to  
ensure reliable operation. For products mounted on a PWB  
without a heat sink attached, cooling is achieved mainly by  
conduction, from the pins to the host board, and convection,  
which is dependant on the airflow across the product.  
Increased airflow enhances the cooling of the product. The  
Output Current Derating graph found in the output section for  
each model provides the available output current vs. ambient  
air temperature and air velocity at VI =53 V.  
The product is tested on a 254 x 254 mm, 35 µm (1 oz),  
16-layer test board mounted vertically in a wind tunnel with a  
cross-section of 608 x 203 mm.  
Definition of product operating temperature  
The product operating temperature is used to monitor the  
temperature of the product, and proper thermal conditions  
can be verified by measuring the temperature at positions  
P1, P2, P3 and P4. The temperature at these positions (TP1,  
TP2, TP3, TP4) should not exceed the maximum temperatures  
in the table below. The number of measurement points may  
vary with different thermal design and topology.  
Temperatures above maximum TP1, measured at the  
reference point P1 (TP3 / P3 for base plate versions) are not  
allowed and may cause permanent damage.  
Position  
P1  
Description  
Max temperature  
TP1=125º C  
PWB (reference point, open  
frame)  
P2  
Opto-coupler  
TP2=105º C  
PWB (reference point for  
base-plate version)  
P3  
TP3=125º C  
P4  
Primary MOSFET  
TP4=125º C  
For products with base plate used in a sealed box/cold wall  
application, cooling is achieved mainly by conduction through  
the cold wall. The Output Current Derating graphs are found in  
the output section for each model. The product is tested in a  
sealed box test set up with ambient temperatures 85, 55 and  
25°C. See Design Note 028 for further details.  