欢迎访问ic37.com |
会员登录 免费注册
发布采购

BMR4560004/004 参数 Datasheet PDF下载

BMR4560004/004图片预览
型号: BMR4560004/004
PDF下载: 下载PDF文件 查看货源
内容描述: 2013- 2013-完全调节高级总线转换器的输入36-75 V,输出可达39 A / 468 W¯¯ [2013- 2013- Fully regulated Advanced Bus Converters Input 36-75 V, Output up to 39 A / 468 W]
分类和应用: 转换器
文件页数/大小: 49 页 / 2235 K
品牌: ERICSSON [ ERICSSON ]
 浏览型号BMR4560004/004的Datasheet PDF文件第36页浏览型号BMR4560004/004的Datasheet PDF文件第37页浏览型号BMR4560004/004的Datasheet PDF文件第38页浏览型号BMR4560004/004的Datasheet PDF文件第39页浏览型号BMR4560004/004的Datasheet PDF文件第41页浏览型号BMR4560004/004的Datasheet PDF文件第42页浏览型号BMR4560004/004的Datasheet PDF文件第43页浏览型号BMR4560004/004的Datasheet PDF文件第44页  
E
40  
Technical Specification  
BMR456 series Fully regulated Advanced Bus Converters  
1/28701-FGC 101 1823 revD February 2013  
© Ericsson AB  
Input 36-75 V, Output up to 39 A / 468 W  
PMBus Interface  
This product provides a PMBus digital interface that enables  
the user to configure many aspects of the device operation as  
well as to monitor the input and output voltages, output current  
and device temperature. The product can be used with any  
standard two-wire I2C or SMBus host device. In addition, the  
product is compatible with PMBus version 1.2 and includes an  
SALERT line to help mitigate bandwidth limitations related to  
continuous fault monitoring. The product supports 100 kHz and  
400 kHz bus clock frequency only. The PMBus signals, SCL,  
SDA and SALERT require passive pull-up resistors as stated in  
the SMBus Specification. Pull-up resistors are required to  
guarantee the rise time as follows:  
Schematic of connection of address resistors.  
Eq. 7 τ = RPCp 1us  
where Rp is the pull-up resistor value and Cp is the bus load.  
The maximum allowed bus load is 400 pF. The pull-up resistor  
should be tied to an external supply between 2.7 to 5.5 V,  
which should be present prior to or during power-up. If the  
proper power supply is not available, voltage dividers may be  
applied. Note that in this case, the resistance in the equation  
above corresponds to parallel connection of the resistors  
forming the voltage divider.  
SA0/SA1 Index  
RSA0/RSA1 [k]  
0
1
10  
22  
33  
2
3
4
5
6
7
47  
68  
100  
150  
220  
It is recommended to always use PEC (Packet Error Check)  
when communicating via PMBus. For these products it is a  
requirement to use PEC when using Send Byte to the device,  
for example command “RESTORE_DEFAULT_ALL”.  
The SA0 and SA1 pins can be configured with a resistor to  
GND according to the following equation.  
Monitoring via PMBus  
A system controller (host device) can monitor a wide variety of  
parameters through the PMBus interface. The controller can  
monitor fault conditions by monitoring the SALERT pin, which  
will be asserted when any number of pre-configured fault or  
warning conditions occur. The system controller can also  
continuously monitor any number of power conversion  
parameters including but not limited to the following:  
PMBus Address = 8 x (SA0value) + (SA1 value)  
If the calculated PMBus address is 0, 11 or 12, PMBus address  
127 is assigned instead. From a system point of view, the user  
shall also be aware of further limitations of the addresses as  
stated in the PMBus Specification. It is not recommended to  
keep the SA0 and SA1 pins left open.  
Input voltage  
Output voltage  
Output current  
Internal junction temperature  
Switching frequency (Monitors the set value not actual  
frequency)  
I2C/SMBus – Timing  
Duty cycle  
Software Tools for Design and Production  
For this products Ericsson provides software for configuring  
and monitoring via the PMBus interface.  
For more information please contact your local  
Ericsson sales representative.  
Setup and hold times timing diagram  
The setup time, tset, is the time data, SDA, must be stable  
before the rising edge of the clock signal, SCL. The hold time  
PMBus Addressing  
t
hold, is the time data, SDA, must be stable after the rising edge  
of the clock signal, SCL. If these times are violated incorrect  
data may be captured or meta-stability may occur and the bus  
communication may fail. When configuring the product, all  
standard SMBus protocols must be followed, including clock  
The following figure and table show recommended resistor  
values with min and max voltage range for hard-wiring PMBus  
addresses (series E12, 1% tolerance resistors suggested):  
 复制成功!