 浏览型号BMR4560004/004的Datasheet PDF文件第32页浏览型号BMR4560004/004的Datasheet PDF文件第33页浏览型号BMR4560004/004的Datasheet PDF文件第34页浏览型号BMR4560004/004的Datasheet PDF文件第35页浏览型号BMR4560004/004的Datasheet PDF文件第37页浏览型号BMR4560004/004的Datasheet PDF文件第38页浏览型号BMR4560004/004的Datasheet PDF文件第39页浏览型号BMR4560004/004的Datasheet PDF文件第40页  
E
36  
Technical Specification  
BMR456 series Fully regulated Advanced Bus Converters  
1/28701-FGC 101 1823 revD February 2013  
© Ericsson AB  
Input 36-75 V, Output up to 39 A / 468 W  
limit, the product can respond in different ways.  
The default response from an over voltage fault is to  
immediately shut down. The device will continuously check for  
the presence of the fault condition, and when the fault  
condition no longer exists the device will be re-enabled.  
The OVP fault level and fault response can be re-configured  
using the PMBus interface.  
use Push-pull when paralleling PG-pins, see  
MFR_MULTI_PIN_CONFIG.  
Synchronization, Tracking and External reference  
This product does not support synchronization, tracking or  
external reference.  
Switching frequency adjust using PMBus  
Over Current Protection (OCP)  
The switching frequency is set to 140 kHz as default but this  
can be reconfigured via the PMBus interface. The product is  
optimized at this frequency but can run at lower and higher  
frequency, (125-150 kHz). The electrical performance can be  
affected if the switching frequency is changed.  
The product includes current limiting circuitry for protection at  
continuous overload. The default setting for the product is hic-  
up mode if the maximum output current is exceeded and the  
output voltage is below 0.3×Vout, set in command  
IOUT_OC_LV_FAULT_LIMIT (0x48). Above the trip voltage  
value in command 0x48 the product will continue operate  
while maintaining the output current at the value set by  
IOUT_OC_FAULT_LIMIT (0x46). The load distribution should  
be designed for the maximum output short circuit current  
specified.  
MFR_MULTI_PIN_CONFIG  
The MFR_MULTI_PIN_CONFIG (0xF9) command enables or  
disables different functions inside the product. This command  
can be configured according to the table for different functions.  
Bit 7:6  
Droop Load Share variants (DLS) will enter hic-up mode, with  
a trip voltage, 0.04×Vout, set in command  
IOUT_OC_LV_FAULT_LIMIT (0x48). Above the trip voltage in  
command (0x48) the product will continue operate while  
maintaining the output current at the value set by  
IOUT_OC_FAULT_LIMIT (0x46).  
00 = Stand alone  
01 = Slave (N/A)  
10 = DLS  
1
1
1
1
1
1
0
0
0
0
0
0
11 = Master (N/A)  
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
1
0
1
Bit 5  
Power Good High Z  
when active  
Bit 4  
Tracking enable  
(N/A)  
Bit 3  
External reference  
(N/A)  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
The over current protection of the product can be reconfigured  
using the PMBus interface.  
Bit 2  
Power Good  
Enable  
Input Over/Under voltage protection  
0
1
0
1
1
1
1
1
1
1
1
1
0
0
0
0
1
0
1
0
1
0
1
0
The input of the product can be protected from high input  
voltage and low input voltage. The over/under-voltage fault  
level and fault response can be configured via the PMBus  
interface.  
Bit 1  
Reserved  
Bit 0  
Secondary Remote  
Control Pull  
up/down resistor  
enable 1)  
0
1
0
1
0
1
0
1
0
1
0
1
Pre-bias Start-up Capability  
The product has a Pre-bias start up functionality and will not  
sink current during start up if a Pre-bias source is present at  
the output terminals. If the Pre-bias voltage is lower than the  
target value set in VOUT_COMMAND (0x21), the product will  
ramp up to the target value. If the Pre-bias voltage is higher  
than the target value set in VOUT_COMMAND (0x21), the  
product will ramp down to the target value and in this case  
sink current for a limited of time set in the command  
TOFF_MAX_WARN_LIMIT (0x66).  
1) When not used  
with PMBus, the  
CTRL input can be  
internally pulled up  
or down depending  
on if it is active high  
or low. When active  
low it will be pulled  
up and vice versa  
The MFR_MULTI_PIN_CONFIG can be reconfigured using  
the PMBus interface. Default configuration is set to Power  
Good Push-Pull (0x04) for stand alone variants and DLS  
Power Good  
The product provides Power Good (PG) flag in the Status  
Word register that indicates the output voltage is within a  
specified tolerance of its target level and no fault condition  
exists. If specified in section Connections, the product also  
provides a PG signal output. The Power Good signal is by  
default configured as active low, Push-pull and can be re-  
configured via the PMBus interface. The Power Good output  
can be configured as Push-pull or “High Z when active” to  
permit AND’ing of parallel devices. It is not recommended to  
Power Good Push-Pull (0x86) for Droop Load Share variants.  
User customized settings  
This product has two data storage set: Default data (Ericsson  
factory) and User data. The User data set’s priority is higher  
than the Default data. The User data area is empty while  
shipped to customer. After boot-up, if the controller found no  
data stored in User data area, it will load Default data instead.  