欢迎访问ic37.com |
会员登录 免费注册
发布采购

BMR4560004/004 参数 Datasheet PDF下载

BMR4560004/004图片预览
型号: BMR4560004/004
PDF下载: 下载PDF文件 查看货源
内容描述: 2013- 2013-完全调节高级总线转换器的输入36-75 V,输出可达39 A / 468 W¯¯ [2013- 2013- Fully regulated Advanced Bus Converters Input 36-75 V, Output up to 39 A / 468 W]
分类和应用: 转换器
文件页数/大小: 49 页 / 2235 K
品牌: ERICSSON [ ERICSSON ]
 浏览型号BMR4560004/004的Datasheet PDF文件第37页浏览型号BMR4560004/004的Datasheet PDF文件第38页浏览型号BMR4560004/004的Datasheet PDF文件第39页浏览型号BMR4560004/004的Datasheet PDF文件第40页浏览型号BMR4560004/004的Datasheet PDF文件第42页浏览型号BMR4560004/004的Datasheet PDF文件第43页浏览型号BMR4560004/004的Datasheet PDF文件第44页浏览型号BMR4560004/004的Datasheet PDF文件第45页  
E
41  
Technical Specification  
BMR456 series Fully regulated Advanced Bus Converters  
1/28701-FGC 101 1823 revD February 2013  
© Ericsson AB  
Input 36-75 V, Output up to 39 A / 468 W  
stretching. Additionally, a bus-free time delay between every  
SMBus transmission (between every stop & start condition)  
must occur. Refer to the SMBus specification, for SMBus  
electrical and timing requirements. Note that an additional  
delay of 5 ms has to be inserted in case of storing the RAM  
content into the internal non-volatile memory.  
Designation  
Cmd Prot  
IOUT_OC_FAULT_RESPONSE  
IOUT_OC_LV_FAULT_LIMIT  
IOUT_OC_WARN_LIMIT  
OT_FAULT_LIMIT  
47h  
48h  
4Ah  
4Fh  
50h  
51h  
52h  
53h  
54h  
55h  
56h  
57h  
58h  
59h  
5Ah  
5Eh  
5Fh  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
OT_FAULT_RESPONSE  
OT_WARN_LIMIT  
PMBus Commands  
The products are PMBus compliant. The following table lists  
the implemented PMBus read commands. For more detailed  
information see PMBus Power System Management Protocol  
Specification; Part I – General Requirements, Transport and  
Electrical Interface and PMBus Power System Management  
Protocol; Part II – Command Language.  
UT_WARN_LIMIT  
UT_FAULT_LIMIT  
UT_FAULT_RESPONSE  
VIN_OV_FAULT_LIMIT  
VIN_OV_FAULT_RESPONSE  
VIN_OV_WARN_LIMIT  
VIN_UV_WARN_LIMIT  
VIN_UV_FAULT_LIMIT  
VIN_UV_FAULT_RESPONSE  
POWER_GOOD_ON  
POWER_GOOD_OFF  
Time setting Commands  
TON_DELAY  
Designation  
Cmd Prot  
Standard PMBus Commands  
Control Commands  
OPERATION  
01h  
02h  
10h  
No  
No  
No  
ON_OFF_CONFIG  
WRITE_PROTECT  
Output Commands  
60h  
61h  
62h  
63h  
64h  
65h  
66h  
No  
No  
No  
No  
No  
No  
No  
VOUT_MODE  
20h  
21h  
22h  
23h  
24h  
25h  
26h  
27h  
29h  
2Ah  
32h  
33h  
35h  
36h  
38h  
39h  
No  
TON_RISE  
VOUT_COMMAND  
VOUT_TRIM  
No  
TON_MAX_FAULT_LIMIT  
TON_MAX_FAULT_RESPONSE  
TOFF_DELAY  
No  
VOUT_CAL_OFFSET  
VOUT_MAX  
Yes  
No  
TOFF_FALL  
VOUT_MARGIN_HIGH  
VOUT_MARGIN_LOW  
VOUT_TRANSITION_RATE  
VOUT_SCALE_LOOP  
VOUT_SCALE_MONITOR  
MAX_DUTY  
No  
TOFF_MAX_WARN_LIMIT  
Status Commands (Read Only)  
CLEAR_FAULTS  
No  
No  
03h  
78h  
79h  
7Ah  
7Bh  
No  
No  
No  
No  
No  
Yes  
Yes  
No  
STATUS_BYTES  
STATUS_WORD  
STATUS_VOUT  
FREQUENCY_SWITCH  
VIN_ON  
No  
STATUS_IOUT  
No  
STATUS_INPUT  
7Ch No  
7Dh No  
VIN_OFF  
No  
STATUS_TEMPERATURE  
STATUS_CML  
IOUT_CAL_GAIN  
Yes  
Yes  
7Eh  
7Fh  
No  
No  
IOUT_CAL_OFFSET  
Fault Commands  
STATUS_OTHER  
Monitior Commands (Read Only)  
READ_VIN  
VOUT_OV_FAULT_LIMIT  
VOUT_OV_FAULT_RESPONSE  
VOUT_OV_WARN_LIMIT  
VOUT_UV_WARN_LIMIT  
VOUT_UV_FAULT_LIMIT  
VOUT_UV_FAULT_RESPONSE  
IOUT_OC_FAULT_LIMIT  
40h  
41h  
42h  
43h  
44h  
45h  
46h  
No  
No  
No  
No  
No  
No  
No  
88h  
8Bh  
No  
No  
READ_VOUT  
READ_IOUT  
8Ch No  
8Dh No  
READ_TEMPERATURE_1  
READ_TEMPERATURE_2  
READ_DUTY_CYCLE  
8Eh  
94h  
No  
No  
 复制成功!