 浏览型号S1D15E06D03E000的Datasheet PDF文件第26页浏览型号S1D15E06D03E000的Datasheet PDF文件第27页浏览型号S1D15E06D03E000的Datasheet PDF文件第28页浏览型号S1D15E06D03E000的Datasheet PDF文件第29页浏览型号S1D15E06D03E000的Datasheet PDF文件第31页浏览型号S1D15E06D03E000的Datasheet PDF文件第32页浏览型号S1D15E06D03E000的Datasheet PDF文件第33页浏览型号S1D15E06D03E000的Datasheet PDF文件第34页  
S1D15E06 Series  
7. COMMAND  
The S1D15E06 series identifies data bus signals by a combination of A0, RD(E) and WR(R/W). Interpretation and  
execution of the command are executed by the internal timing alone which is independent of the external clock. This  
allows high-speed processing.  
The 80 series MPU interface allows the command to be started by entering the low pulse in the RD pin during reading  
and by entering the low pulse in the WR pin during writing.  
The 68 series MPU interface allows a read state to occur by entering HIGH in the R/W pin, and permits a write state  
to occur by entering LOW. It also allows the command to be started by entering the high pulse in the pin E. (For timing,  
see the description of “10. Timing characteristics”).  
Accordingly, the 68 series MPU interface is different from 80 series MPU interface in that RD(E) is “1(H)” in the case  
of display data/read shown in the Command Description and Command Table. The following describes the commands,  
based on the example of the 80 series MPU interface:  
When the serial interface is selected, enter data sequentially starting from D7.  
Command Description  
(1) Display ON/OFF  
This command sets the display ON/OFF.  
When display OFF is specified, segment and common drivers outputs the level selected by the display OFF Mode Select  
command.  
E
RD  
R/W  
WR  
A0  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0 Output level  
0
1
0
1
0
1
0
1
1
1
0
1
Display OFF  
Display ON  
(2) Display OFF Mode Select  
This command is used to set the output level of the segment and common driver when the display is off.  
In the initial setting state, it becomes "D0 = 0".  
* When D0 = 0 is selected in the case of S1D15E06D00B , the MV2 and common driver VSS level is output by segment  
*
driver when display is off. Select D0 = 1 to use the S1D15E06D00B .  
*
E
RD  
R/W  
WR  
A0  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0 Output level  
0
1
0
1
0
1
1
1
1
1
0
1
VSS  
VC  
(3) Display Normal/Reverse  
This command allows the display ON/OFF state to be reversed, without having to rewrite the contents of the display  
data RAM. In this case, contents of the display data RAM are maintained.  
E
RD  
R/W  
WR  
A0  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
Setting  
0
1
0
1
0
1
0
0
1
1
0
RAM data = HIGH  
LCD ON Voltage  
(normal)  
1
RAM data = LOW  
LCD ON Voltage  
(reverse)  
Rev. 2.1  