EM47FM3288SBB
2. CKE Truth Table
CKE
Command (n)
Current State
Power Down
Self Refresh
Action (n)
Notes
/RAS, /CAS, /WE, /CS
X
n-1
L
n
L
H
L
H
L
L
L
L
L
L
L
Maintain power down
Power down exit
14,15
L
DESELECT or NOP
X
11,14
L
Maintain self refresh
Self refresh exit
15,16
L
DESELECT or NOP
DESELECT or NOP
DESELECT or NOP
DESELECT or NOP
DESELECT or NOP
DESELECT or NOP
DESELECT or NOP
REFRESH
8,12,16
Bank Active
Reading
H
H
H
H
H
H
H
Active power down entry
Power down entry
Power down entry
Power down entry
11,13,14
11,13,14,17
11,13,14,17
11,13,14,17
Writing
Precharging
Refreshing
Precharge power down entry 11
Precharge power down entry 11,13,14,18
All Banks Idle
Self refresh
9,13,18
10
For more details with all signals, see “Command Truth Table”
Note1. CKE (n) is the logic state of CKE at clock edge n; CKE (n-1) was the state of CKE at the previous clock
edge.
Note2. Current state is defined as the state of the DDR3 SDRAM immediately prior to clock edge n.
Note3. Command (n) is the command registered at clock edge n, and ACTION (n) is a result of Command (n),
ODT is not included here.
Note4. All states and sequences not shown are illegal or reserved unless explicitly described elsewhere in this
document.
Note5. The state of ODT does not affect the states described in this table. The ODT function is not available
during Self-Refresh.
Note6. During any CKE transition (registration of CKE H->L or CKE L->H) the CKE level must be maintained
until 1nCK prior to tCKEmin being satisfied (at which time CKE may transition again).
Note7. DESELECT and NOP are defined in the “Command Truth Table”.
Note8. On self-refresh exit DESELECT or NOP commands must be issued on every clock edge occurring
during the tXS period. Read or ODT commands may be issued only after tXSDLL is satisfied.
Note9. Self-Refresh mode can only be entered from the All Banks Idle state.
Note10. It must be a legal command as defined in the “Command Truth Table”.
Note11. Valid commands for power-down entry and exit are NOP and DESELECT only.
Note12. Valid commands for self-refresh exit are NOP and DESELECT only.
Note13. Self-Refresh can not be entered during Read or Write operations.
Note14. The Power-Down does not perform any refresh operations.
Note15. “X” means “don’t care“ (including floating around VREF) in Self-Refresh and Power-Down. It also
applies to Address pins.
Note16. VREF (Both VREFDQ and VREFCA) must be maintained during Self-Refresh operation. VREFDQ
supply may be turned OFF and VREFDQ may take any value between VSS and VDD during Self Refresh
Jul. 2012
29/41
www.eorex.com