EM65101  
128COM/160SEG 16 Gray Scale Level LCD Driver  
8.2.4 Display Control Display (1) Register  
D7 D6 D5 D4 D3 D2 D1 D0  
CSB RS RDB WRB RE2 RE1 RE0  
ALL ON/  
ON OFF  
SHIFT  
0
1
0
1
0
1
1
0
0
0
0
*
(At the time of reset: {SHIFT, ALLON, ON/OFF}=0H, read address: 5H)  
ON/OFF: Control display ON/OFF  
ON/OFF = “0”: Display OFF  
ON/OFF = “1”: Display ON  
ALLON: Regardless of the data for display, all is ON.  
This control has priority over display normal/reverse commands.  
ALLON = “0”: Normal display  
ALLON = “1”: All display lighted  
SHIFT  
The shift direction of display scanning data in the common driver output is selected.  
SHIFT = “0”: COM0COM127 shift-scan  
SHIFT = “1”: COM127COM0 shift-scan  
8.2.5 Display Control (2) Register  
D7 D6 D5 D4 D3 D2 D1 D0  
REV NLIN EOR REF  
CSB RS RDB WRB RE2 RE1 RE0  
0
1
1
0
0
1
1
0
0
0
0
(At the time of reset: {REV, NLIN, EOR, REF} = 0H, read address: 6H)  
REV: To the corresponding display RAM data, the lighting or non-lighting control of the  
display is set.  
REV =”0”: When RAM data is “H,” and LCD at ON voltage (normal)  
REV =”1”: When RAM data is “L,” and LCD at ON voltage (reverse)  
NLIN: The n-line alternate drive NLIN control.  
NLIN = “0”: n-line alternate drive is OFF. In each frame, the alternate signals (M) are  
reversed.  
NLIN =”1”: n-line alternated drive is ON. Depending on data set up in the n-line  
alternated register, alternation is made.  
EOR: The n-line alternate drive EOR control.  
EOR=0: M always reverses at the nth raster row regardless of whether the end of a  
frame is reached.  
EOR=1: M reverses at the nth raster row and restarts the raster row count at the start  
of every frame.  