EDS6432AFTA, EDS6432CFTA
Test Conditions
[EDS6432AF]
• AC high level voltage/low level input voltage: 2.4V/0.4V
• Input and output timing reference levels: 1.4V
• Output timing measurement reference level: 1.4V
• Input waveform and output load: See following figures
2.4 V
I/O
2.0 V
input
0.8 V
0.4 V
CL
t
T
tT
Input waveform and Output load [EDS6432AF]
[EDS6432CF]
• AC high level voltage/low level input voltage: 2.1V/0.3V
• Input and output timing reference levels: 1.2V
• Output timing measurement reference level: 1.2V
• Input waveform and output load: See following figures
2.1 V
I/O
1.7 V
input
0.7 V
0.3 V
CL
t
T
tT
Input waveform and Output load [EDS6432CF]
Data Sheet E0487E50 (Ver. 5.0)
8