 浏览型号CY7C68013A-128AXI的Datasheet PDF文件第42页浏览型号CY7C68013A-128AXI的Datasheet PDF文件第43页浏览型号CY7C68013A-128AXI的Datasheet PDF文件第44页浏览型号CY7C68013A-128AXI的Datasheet PDF文件第45页浏览型号CY7C68013A-128AXI的Datasheet PDF文件第47页浏览型号CY7C68013A-128AXI的Datasheet PDF文件第48页浏览型号CY7C68013A-128AXI的Datasheet PDF文件第49页浏览型号CY7C68013A-128AXI的Datasheet PDF文件第50页  
CY7C68013A/CY7C68014A  
CY7C68015A/CY7C68016A  
10.10 Slave FIFO Asynchronous Write  
t
WRpwh  
SLWR  
t
WRpwl  
t
t
FDH  
SFD  
DATA  
t
XFD  
FLAGS  
Figure 10-10. Slave FIFO Asynchronous Write Timing Diagram[20]  
Table 10-11. Slave FIFO Asynchronous Write Parameters with Internally Sourced IFCLK [23]  
Parameter  
tWRpwl  
tWRpwh  
tSFD  
Description  
Min.  
50  
Max.  
Unit  
ns  
SLWR Pulse LOW  
SLWR Pulse HIGH  
70  
ns  
SLWR to FIFO DATA Set-up Time  
FIFO DATA to SLWR Hold Time  
10  
ns  
tFDH  
10  
ns  
tXFD  
SLWR to FLAGS Output Propagation Delay  
70  
ns  
10.11 Slave FIFO Synchronous Packet End Strobe  
IFCLK  
t
PEH  
PKTEND  
FLAGS  
t
SPE  
t
XFLG  
Figure 10-11. Slave FIFO Synchronous Packet End Strobe Timing Diagram[20]  
Table 10-12. Slave FIFO Synchronous Packet End Strobe Parameters with Internally Sourced IFCLK[21]  
Parameter  
tIFCLK  
Description  
Min.  
20.83  
14.6  
0
Max.  
Unit  
ns  
IFCLK Period  
tSPE  
tPEH  
tXFLG  
PKTEND to Clock Set-up Time  
ns  
Clock to PKTEND Hold Time  
ns  
Clock to FLAGS Output Propagation Delay  
9.5  
ns  
Table 10-13. Slave FIFO Synchronous Packet End Strobe Parameters with Externally Sourced IFCLK[21]  
Parameter  
tIFCLK  
Description  
Min.  
20.83  
8.6  
Max.  
Unit  
ns  
IFCLK Period  
200  
tSPE  
tPEH  
tXFLG  
PKTEND to Clock Set-up Time  
ns  
Clock to PKTEND Hold Time  
2.5  
ns  
Clock to FLAGS Output Propagation Delay  
13.5  
ns  
There is no specific timing requirement that needs to be met  
for asserting PKTEND pin with regards to asserting SLWR.  
PKTEND can be asserted with the last data value clocked into  
the FIFOs or thereafter. The only consideration is the set-up  
time tSPE and the hold time tPEH must be met.  
Although there are no specific timing requirements for the  
PKTEND assertion, there is a specific corner case condition  
that needs attention while using the PKTEND to commit a one  
byte/word packet. There is an additional timing requirement  
that need to be met when the FIFO is configured to operate in  