CY7B951
Electrical Characteristics
Over the Operating Range (continued)
Parameter
V
IDIFF
V
IHE
Description
Input Differential Voltage TSER/RIN
REFCLK
Input High Voltage
TSER/RIN
REFCLK
CD
V
ILE
Input LOW Voltage
TSER/RIN
REFCLK
CD (ECL)
CD (Disable)
ECL Compatible Output Pins (ROUT±, RCLK±, RSER±, TOUT±, TCLK±)
V
OHE
V
OLE
V
ODIFF
V
IHH
V
IMM
V
ILL
I
CCS
I
CCR
I
CCT
I
CCE
I
CC5
I
CCO
ECL Output HIGH Voltage
ECL Output LOW Voltage
Output Differential Voltage
Three-Level Input HIGH
Three-Level Input MID
Three-Level Input LOW
Static Operating Current
Receiver Operating Current
Transmitter Operating Current
ECL Pair Operating Current
Additional Current 51.84 MHz
Additional Current LFI = LOW
Commercial
Industrial
T > 0°C
V
CC
– 1.03
V
CC
– 1.08
V
CC
– 1.86
0.6
V
CC
– 0.75
V
CC
/2 – 0.5
0.0
V
CC
V
CC
/2 + 0.5
0.75
30
50
13
7.0
7.0
3
V
CC
– 0.83
V
CC
– 0.83
V
CC
– 1.62
V
V
V
V
V
V
V
mA
mA
mA
mA
mA
mA
3.0
V
CC
– 1.165
2.0
2.5
2.5
–0.5
V
CC
– 1.475
0.8
Test Condition
Min.
50
100
Max.
1200
1200
V
CC
V
CC
V
CC
Unit
mV
mV
V
V
V
V
V
V
V
Three-Level Input Pins (MODE)
Operating Current
Capacitance
Parameter
C
IN
Description
Input Capacitance
Test Conditions
T
A
= 25°C, f
0
= 1 MHz, V
CC
= 5.0V
Max.
10
Unit
pF
Notes
4. Specified only for temperatures below 0°C.
5. Total Receiver operating current (assuming that the Transmitter is not activated) can be found by adding I
CCS
+ I
CCR
+ x * I
CCE
; where x is 2 if the ROUT± outputs
are not activated and 3 if they are activated.
Total Transmitter operating current (assuming that the Receiver is not activated) can be found by adding I
CCS
+ I
CCT
+ x * I
CCE
; where x is 1 if the TOUT± outputs
are not activated and 2 if they are activated.
Total device power (assuming that the Transmitter and the Receiver are activated) can be found by adding I
CCS
+ I
CCR
+ I
CCT
+ x * I
CCE
; where x represents
the number of ECL output pairs activated.
6. Tested initially and after any design or process changes that may affect these parameters.
Document Number: 38-02010 Rev. *A
Page 6 of 10