PLDC20RA10
Static Discharge Voltage ........................................... >2001V
(per MIL-STD-883, Method 3015)
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Latch-Up Current..................................................... >200 mA
DC Program Voltage .................................................... 13.0V
Storage Temperature .................................–65°C to +150°C
Ambient Temperature with
Power Applied.............................................–55°C to +125°C
Operating Range
Ambient
Supply Voltage to Ground Potential
(Pin 24 to Pin 12) ........................................... –0.5V to +7.0V
Range
Commercial
Military[2]
Temperature
VCC
0°C to +75°C
5V ± 10%
5V ± 10%
DC Voltage Applied to Outputs
in High Z State............................................... –0.5V to +7.0V
–55°C to +125°C
DC Input Voltage......................................... –3.0 V to + 7.0 V
]
Output Current into Outputs (LOW) .............................16 mA
Electrical Characteristics Over the Operating Range[3]
Parameter
Description
Test Conditions
IOH = –3.2 mA
IOH = –2 mA
IOL = 8 mA
Min. Max. Unit
VOH
Output HIGH Voltage
VCC = Min.,
VIN =VIH or VIL
Com’l
2.4
V
Mil
VOL
Output LOW Voltage
VCC = Min.,
0.5
V
VIN = VIH or VIL
VIH
VIL
IIX
Input HIGH Level
Guaranteed Input Logical HIGH Voltage for All Inputs[4]
Guaranteed Input Logical LOW Voltage for All Inputs[4]
2.0
V
Input LOW Level
0.8
+10
+40
–90
75
V
Input Leakage Current
Output Leakage Current
Output Short Circuit Current[5]
VSS ≤ VIN ≤ VCC, VCC = Max
–10
–40
–30
µA
µA
mA
mA
mA
mA
mA
IOZ
ISC
ICC1
VCC = Max., VSS ≤ VOUT ≤ VCC
VCC = Max., VOUT = 0.5V[6]
Standby Power Supply Current VCC= Max., VIN = GND Outputs Open
Com’l
Mil
80
ICC2
Power Supply Current at
Frequency[5]
VCC = Max., Outputs Disabled (In High Z
State) Device Operating at fMAX
Com’l
Mil
80
85
Capacitance[5]
Parameter
Description
Test Conditions
VIN = 2.0 V @ f = 1 MHz
VOUT = 2.0 V @ f = 1 MHz
Max.
Unit
CIN
Input Capacitance
Output Capacitance
10
10
pF
pF
COUT
Notes:
2. TA is the “instant on” case temperature.
3. See the last page of this specification for Group A subgroup testing information.
4. These are absolute values with respect to device ground and all overshoots due to system or tester noise are included.
5. Tested initially and after any design or process changes that may affect these parameters.
6. Not more than one output should be tested at a time. Duration of the short circuit should not be more than one second. VOUT = 0.5 V has been chosen to
avoid test problems caused by tester ground degradation.
Document #: 38-03012 Rev. **
Page 5 of 14