PLDC20RA10
Switching Characteristics Over the Operating Range[3, 7, 8]
Commercial
Military
–15
–20
–20
–25
–35
Parameter
tPD
Description
Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Unit
Input or Feedback to
Non-Registered Output
15
20
20
25
35
ns
tEA
tER
Input to Output Enable
15
15
20
20
20
20
30
30
35
35
ns
ns
Input to Output
Disable
tPZX
tPXZ
Pin 13 to Output
Enable
12
12
15
15
15
20
15
15
20
20
20
25
25
25
35
ns
ns
Pin 13 to Output
Disable
tCO
tSU
Clock to Output
ns
ns
Input or Feedback
Set-Up Time
7
10
10
15
20
tH
tP
Hold Time
3
5
3
5
5
ns
ns
Clock Period
(tSU + tCO)
22
30
30
40
55
tWH
tWL
Clock Width HIGH[5]
Clock Width LOW[5]
10
10
13
13
12
12
18
18
25
25
ns
ns
fMAX
Maximum Frequency
(1/tP)[5]
45.5
33.3
33.3
25.0
18.1
MHz
tS
tR
Input of Asynchronous
Set to Registered Output
15
15
20
20
20
20
25
25
40
40
ns
ns
Input of Asynchronous
Reset to Registered
Output
tARW
Asynchronous Reset
Width[5]
15
20
20
25
25
ns
tASW
tAR
Asynchronous S-Width[5]
15
10
20
12
20
12
25
15
25
20
ns
ns
Asynchronous Set/
Reset Recovery Time
tWP
Preload Pulse Width
Preload Set-Up Time
Preload Hold Time
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
ns
ns
ns
tSUP
tHP
Notes:
7. Part (a) of AC Test Loads was used for all parameters except tEA, tER, tPZX and tPXZ, which use part (b).
8. The parameters tER and tPXZ are measured as the delay from the input disable logic threshold transition to VOH - 0.5 V for an enabled HIGH output or VOL
+0.5V for an enabled LOW output. Please see part (c) of AC Test Loads and Waveforms for waveforms and measurement reference levels.
Document #: 38-03012 Rev. **
Page 7 of 14