PRELIMINARY
CYW54907
13. Electrical Characteristics
Note: Values in this data sheet are design goals and are subject to change based on the results of device characterization.
13.1 Absolute Maximum Ratings
Caution! The absolute maximum ratings in Table 15 indicate levels where permanent damage to the device can occur, even if these
limits are exceeded for only a brief duration. Functional operation is not guaranteed under these conditions. Operation at absolute
maximum conditions for extended periods can adversely affect long-term reliability of the device.
Table 15. Absolute Maximum Ratings
Parameter
DC supply for VBAT and PA driver supply a
DC supply voltage for digital I/O
Symbol
Value
Unit
V
VBAT
–0.5 to +5.5
–0.5 to 3.9
–0.5 to 3.9
–0.5 to 3.9
–0.5 to 3.9
–0.5 to 3.9
–0.5 to 1.575
–0.5 to 3.9
VDDIO
V
DC supply voltage for I2S I/O
VDDIO_I2S
VDDIO_RF
VDDIO_RMII
VDDIO_SD
–
V
DC supply voltage for RF switch I/O
DC supply voltage for Ethernet I/O
DC supply voltage for SDIO I/O
V
V
V
DC input supply voltage for CLDO, LNLDO, and BBPLL LDOb
V
3.3V DC supply for USB
USB2_AVDD33
USB2_AVDD33LDO
USB2_AVDD33IO
VDD3P3RF
VDD1P35RF
VDD1P2RF
VDD1P2A
V
3.3V DC supply voltage for RF analogc
1.35V DC supply voltage for RF analogd
1.2V DC supply voltage for RF analoge
1.2V DC supply voltage for analog circuitsf
DC supply voltage for the coreg
–0.5 to 3.6
–0.5 to 1.5
–0.5 to 1.26
–0.5 to 1.26
–0.5 to 1.32
–0.5 to 3.9
–0.5
V
V
V
V
VDDC
V
DC supply voltage for OTP memory
Maximum undershoot voltage for I/O
Maximum junction temperature
OTP_VDD3P3
Vundershoot
Tj
V
V
125
°C
a. For the SR_VDDBAT5V and LDO_VDDBAT5V supplies.
b. For the LDO_VDD1P5 and WRF_XTAL_VDD1P35 supplies.
c. For the WRF_SYNTH_VDD3P3, WRF_PA_VDD3P3, and WRF_TXMIX_VDD supplies.
d. For WRF_PMU_VDD1P35 and WRF_AFE_VDD1P35 supplies.
e. For the WRF_SYNTH_VDD1P2 supply.
f. For the AVDD1P2_AUDIO, AVDD1P2, and HSIC_AVDD12 supplies.
g. For the VDD, HSIC_DVDD12, and HSIC2_DVDD2 supplies.
13.2 Environmental Ratings
The environmental ratings are shown in Table 16.
Table 16. Environmental Ratings
Characteristic
Ambient temperature (TA)
Value
Units
°C
Conditions/Comments
–30 to +85
–40 to +125
Less than 60
Less than 85
Functional operation
Storage temperature
Relative humidity
°C
–
%
Storage
Operation
%
Document Number: 002-19312 Rev. *C
Page 50 of 95