D A T A S H E E T
AC CHARACTERISTICS
555 for program
PA for program
2AA for erase
SA for sector erase
555 for chip erase
Data# Polling
Addresses
PA
tWC
tWH
tAS
tAH
WE#
OE#
tGHEL
tWHWH1 or 2
tCP
CE#
Data
tWS
tCPH
tDS
tBUSY
tDH
DQ7#
DOUT
tRH
A0 for program
55 for erase
PD for program
30 for sector erase
10 for chip erase
RESET#
RY/BY#
Notes:
1. PA = Program Address, PD = Program Data, SA = Sector Address, DQ7# = Complement of Data Input, DOUT = Array Data.
2. Figure indicates the last two bus cycles of the command sequence, with the device in word mode.
Figure 19. Alternate CE# Controlled Write Operation Timings
November 11, 2009 21505E8
Am29F400B
35