欢迎访问ic37.com |
会员登录 免费注册
发布采购

39K200 参数 Datasheet PDF下载

39K200图片预览
型号: 39K200
PDF下载: 下载PDF文件 查看货源
内容描述: CPLD器件的FPGA DensitiesTM [CPLDs at FPGA DensitiesTM]
分类和应用:
文件页数/大小: 86 页 / 1209 K
品牌: CYPRESS [ CYPRESS SEMICONDUCTOR ]
 浏览型号39K200的Datasheet PDF文件第5页浏览型号39K200的Datasheet PDF文件第6页浏览型号39K200的Datasheet PDF文件第7页浏览型号39K200的Datasheet PDF文件第8页浏览型号39K200的Datasheet PDF文件第10页浏览型号39K200的Datasheet PDF文件第11页浏览型号39K200的Datasheet PDF文件第12页浏览型号39K200的Datasheet PDF文件第13页  
Delta39K™ ISR™
CPLD Family
All channel memory
inputs are driven from
the routing channels
4096-bit Dual-Port
Array
Configurable as
Async/Sync Dual-Port
or Sync FIFO
Vertical Channel
Configurable as
4K x 1, 2K x 2, 1K x 4,
and 512 x 8 block sizes
Global Clock
Signals
GCLK[3:0]
All channel memory outputs
drive dedicated tracks in the
routing channels
Horizontal Channel
Figure 6. Block Diagram of Channel Memory Block
I/O Banks
The Delta39K interfaces the horizontal and vertical routing
channels to the pins through I/O banks. There are eight I/O
banks per device as shown in
Figure 7,
and all I/Os from an
I/O bank are located in the same section of a package for PCB
layout convenience.
Delta39K devices support True Vertical Migration™ (i.e., for
each package type, Delta39K devices of different densities
keep given pins in the same I/O banks). This allows for easy
and simple implementation of multiple I/O standards during the
design and prototyping phase, before a final density has been
determined. Please refer to the application note titled
“Family,
Package and Density Migration in Delta 39K and Quantum38K
CPLDs.”
Each I/O bank contains several I/O cells, and each I/O cell
contains an input/output register, an output enable register,
programmable slew rate control and programmable bus hold
control logic. Each I/O cell drives a pin output of the device;
the cell also supplies an input to the device that connects to a
dedicated track in the associated routing channel.
Each I/O bank can use any supported I/O standard by
supplying appropriate V
REF
and V
CCIO
voltages and config-
uring the I/O through the Warp software. All the V
REF
and
V
CCIO
pins in an I/O bank must be connected to the same V
REF
and V
CCIO
voltage respectively. This requirement restricts the
number of I/O standards supported by an I/O bank at any given
time.
The number of I/Os which can be used in each I/O bank
depend on the type of I/O standards and the number of V
CCIO
and GND pins being used. This restriction is derived from the
electromigration limit of the V
CCIO
and GND bussing on the
chip. Please refer to the note on page 17 and the application
note titled
“Delta39K Family Device I/O Standards and Config-
urations”
for details.
I/O Cell
Figure 8
is a block diagram of the Delta39K I/O cell. The I/O
cell contains a three-state input buffer, an output buffer, and a
register that can be configured as an input or output register.
The output buffer has a slew rate control option that can be
used to configure the output for a slower slew rate. The input
of the device and the pin output can each be configured as
registered or combinatorial; however, only one path can be
configured as registered in a given design.
The output enable in an I/O cell can be selected from one of
the four global control signals or from one of two Output
Control Channel (OCC) signals. The output enable can be
configured as always enabled or always disabled or it can be
controlled by one of the remaining inputs to the mux. The
selection is done via a mux that includes V
CC
and GND as
inputs.
bank 7
bank 1 bank 0
bank 6
bank 4 bank 5
Page 9 of 86
Delta39K
Delta39K
bank 2
bank 3
Figure 7. Delta39K I/O Bank Block Diagram
Document #: 38-03039 Rev. *H