 浏览型号CBC915-ACA-TR1的Datasheet PDF文件第7页浏览型号CBC915-ACA-TR1的Datasheet PDF文件第8页浏览型号CBC915-ACA-TR1的Datasheet PDF文件第9页浏览型号CBC915-ACA-TR1的Datasheet PDF文件第10页浏览型号CBC915-ACA-TR1的Datasheet PDF文件第12页浏览型号CBC915-ACA-TR1的Datasheet PDF文件第13页浏览型号CBC915-ACA-TR1的Datasheet PDF文件第14页浏览型号CBC915-ACA-TR1的Datasheet PDF文件第15页  
CBC915 EnerChip Energy Processor  
@<X>,<DDDD><cr><lf>>0  
Where <X> is an ASCII decimal number echoing the command number and <DDDD> is a specific length (4 digits  
in this case) ASCII decimal number. Notice the ASCII comma character between the command number and data  
parameter and the ASCII zero following the <cr>  
Example:  
@2,05<cr><lf>>0 is a response from command 2 that the CBC915 is in state 5.  
Response 1 (Not available on CBC915-ACA): Power Available  
<@> <command number> <comma> <XXXXX> <line feed> <carriage return> <zero>  
XXXXX= ASCII numbers for microwatts of power (1-99999)  
Example: Command request for power available #<sp>1<cr> ;where <sp> = ASCII space character and  
<cr> = ASCII carriage return character  
Command returns @1,00237<cr><lf>0 Where 00237 is 237uW of power available and <lf> is ASCII  
line feed character  
Response 2 (Not available on CBC915-ACA): State of CBC915  
<@> <command number> <comma> <XX><carriage return> <line feed> <zero>  
XX= ASCII numbers for State (1-99)  
State 1 = MPPT mode  
State 2 = Capacitor charging  
State 3 = EnerChip(s) charging  
State 4 = System in regulation  
State 5 = Output off  
Response 3 (Not available on CBC915-ACA: Transducer Type  
<@> <command number> <comma> <XX> <carriage return> <line feed> <zero>  
XX= ASCII numbers for transducer type (1-99)  
Transducer 1 = Low voltage input; typically TEG  
Transducer 2 = PV cell input  
Transducer 3 = High voltage input; typically piezoelectric  
Transducer4=Mediumvoltageinput,constantimpedance transducers;typicallyelectromagnetic  
generators  
Response 4: Find Maximum Peak Power Point  
<@> <command number> <comma> <ack> <carriage return> <line feed> <zero>  
<ack>= ASCII ACK  
Response 5: EnerChip State of Charge  
<@> <command number> <comma> <XXX><carriage return> <line feed> <zero>  
XXX= ASCII numbers as percent of full charge (requires command to be requested twice for accurate  
data)  
Response 6: Calibrate EnerChip EP  
<@> <command number> <comma> <XXXX> <carriage return> <line feed> <zero>  
XXXX= ASCII numbers for A/D reading for 4.06 volts  
Response 7: Returns data from Command 1, Command 2, Command 3, and Command 5  
©2012 Cymbet Corporation • Tel: +1-763-633-1780 • www.cymbet.com  
DS-72-15 Rev F  
Page 11 of 16