 浏览型号CBC3150-D9C-WP的Datasheet PDF文件第5页浏览型号CBC3150-D9C-WP的Datasheet PDF文件第6页浏览型号CBC3150-D9C-WP的Datasheet PDF文件第7页浏览型号CBC3150-D9C-WP的Datasheet PDF文件第8页浏览型号CBC3150-D9C-WP的Datasheet PDF文件第10页浏览型号CBC3150-D9C-WP的Datasheet PDF文件第11页浏览型号CBC3150-D9C-WP的Datasheet PDF文件第12页浏览型号CBC3150-D9C-WP的Datasheet PDF文件第13页  
EnerChip CC CBC3150
EnerChip CC Detailed Description
The EnerChip CC uses a charge pump to generate the supply voltage for charging the integrated energy storage
device. An internal FET switch with low RDS
ON
is used to route V
DD
to V
OUT
during normal operation when main
power is above the switchover threshold voltage. When V
DD
is below the switchover threshold voltage, the
FET switch is shut off and V
OUT
is supplied by the EnerChip. An interrupt signal is asserted low prior to the
switchover.
Operating Modes
The EnerChip CC can be operated from various power supplies such as a primary source or a non-rechargeable
battery. With the ENABLE pin asserted high, the charge pump is active and charges the integrated EnerChip.
The EnerChip CC will be 80% charged within 20 minutes. Due to the rapid recharge it is recommended that,
once the EnerChip CC is fully charged, the user de-assert the ENABLE pin (i.e., force low) to reduce power
consumption. A signal generated from the MCU could be used to enable and disable the EnerChip CC.
When controlling the ENABLE pin by way of an external controller - as opposed to fixing the ENABLE line to VDD
- ensure that the ENABLE pin is forced low by the controller anytime the RESET line is low, which occurs when
the switchover threshold voltage is reached and the device is placed in backup mode. Although the internal
charge pump is designed to operate below the threshold switchover level when the ENABLE line is active, it
is recommended that the ENABLE pin be forced low whenever RESET is low to ensure no parasitic loads are
placed on the EnerChip while in this mode. If ENABLE is high or floating while VDD is in an indeterminate
state, bias currents within the EnerChip CC could flow, placing a parasitic load on the EnerChip that could
dramatically reduce the effective backup operating time.
The EnerChip CC supports 2 operational modes as shown in Figures 6 and 7.
DS-72-03 Rev C
©2009-2010 Cymbet Corporation • Tel: +1-763-633-1780 • www.cymbet.com
Page 9 of 15