Crane Aerospace & Electronics Power Solutions
sLH sꢂꢄglꢃ ꢀꢄꢆ dꢇꢀl dc/dc cꢈꢄvꢃꢉꢊꢃꢉꢁ
28 VoLt input – 1.5 Watt – pendinꢋ reVision c reLease
sMd nuMbers
ModeL nuMberinꢋ Keꢍ
St a n D a r D Mi C r O C i r C u i t
SLH SiMiLar pa r t
Dr a w i n g (SMD)
SLH
28 12 D / K
R
5962R0052601KXC
5962R0052701KXC
5962R0052801KXC
5962R0250401KXC
5962R9955601KXC
5962R9852901KXC
SLH2805S/KR
SLH2812S/KR
SLH2815S/KR
SLH2805D/KR
SLH2812D/KR
SLH2815D/KR
Base Model
Input Voltage
Output Voltage
Number of Outputs
(S = single, D = dual)
Screening
Radiation Hardness
Assurance (RHA)
The SMD number shown is for Class K screening and Radiation
Hardness Assurance (RHA) level R. See the SMD for the numbers
for other screening and radiation levels. For exact specifications
for an SMD product, refer to the SMD drawing. Call your Interpoint
representative for status on the SMTR SMD releases which are
“in process.” SMDs can be downloaded from:
http://www.dscc.dla.mil/programs/smcr
ModeL seLection
en t e r O n e Se L e C t i O n F r O M e a C H C a t e g O r y
SLH28
/
2
3
4
BASE MODEL
V
VALUE
ꢀUMBER OF
OUTPUTS
CASE OPTIOꢀ
SCREEꢀIꢀꢁ
RHA
OUT
1
5
s
d
ꢀO CASE OPTIOꢀS FOR SLH
o
H
K
o
r
12
15
ꢀotes:
1. S is a single output and D is a dual output
2. There are not case options for the SLH. Only the standard case is available.
3. A screening level of O is a Space Prototype and is only used with RHA O.
4. Interpoint model numbers use an “O” in the RHA designator position to indicate the “-” (dash) Radiation Hardness Assurance level of MIL-PRF-38534, which is
defined as “no RHA. RHA O is only available with Screening level O. For more information see page 10.
www.interpoint.com
Page 4 of 10
Rev C - 20090318 - Pending Revision C Release