4.0 Registers
RS8953B/8953SPB
4.18 PRA Receive Write
HDSL Channel Unit
Sa
The new value to be inserted into the Sa location of the data stream, in the HDSL to PCM
5
5
direction. Sa is used in all odd frames.
5
Sa _1, _2, _3, _4 The new value to be inserted into the Sa _1, _2, _3, _4 location of the data stream, in the
6
6
HDSL to PCM direction. Sa _1 is used in Frames 1 and 9. Sa _2 is used in Frames 3 and 11.
6
6
Sa _3 is used in Frames 5 and 13. Sa _4 is used in Frames 7 and 15.
6
6
4-80
Conexant
N8953BDSB