CX82100 Home Network Processor Data Sheet
Bit(s)
15
Type
RR
Default
1’b0
Name
EP3I_ERRCNT_INT
Description
Endpoint 3 IN Error Count Interrupt.
0 = Endpoint 3 IN retries count not exceeded.
1 = Endpoint 3 IN retries count exceeded.
Endpoint 2 IN Error Count Interrupt.
0 = Endpoint 2 IN retries count not exceeded.
1 = Endpoint 2 IN retries count exceeded.
Endpoint 1 IN Error Count Interrupt.
0 = Endpoint 1 IN retries count not exceeded.
1 = Endpoint 1 IN retries count exceeded.
Endpoint 0 IN Error Count Interrupt.
14
13
12
11
RR
RR
RR
RR
1’b0
1’b0
1’b0
1’b0
EP2I_ERRCNT_INT
EP1I_ERRCNT_INT
EP0I_ERRCNT_INT
INTRNEXT_INT
0 = Endpoint 0 IN retries count not exceeded.
1 = Endpoint 0 IN retries count exceeded.
Interrupt Channel Requesting Next Interrupt.
0 = Interrupt channel not requesting second dword write of
interrupt data.
1 = Interrupt channel requesting second dword write of
interrupt data.
10
9
8
7
6
5
4
3
2
1
0
RR
RR
RR
RR
RR
RR
RR
RR
RR
RR
RR
1’b0
1’b0
1’b0
1’b0
1’b0
1’b0
1’b0
1’b0
1’b0
1’b0
1’b0
INTRDN_INT
EP3I_INT
Interrupt Channel Transmission Done Interrupt.
0 = Interrupt channel transmission is not complete.
1 = Interrupt channel transmission is complete.
Endpoint 3 IN Transmission Complete Interrupt.
0 = Endpoint 3 IN channel transmission is not complete.
1 = Endpoint 3 IN channel transmission is complete.
Endpoint 2 IN Transmission Complete Interrupt.
0 = Endpoint 2 IN channel transmission is not complete.
1 = Endpoint 2 IN channel transmission is complete.
Endpoint 1 IN Transmission Complete Interrupt.
0 = Endpoint 1 IN channel transmission is not complete.
1 = Endpoint 1 IN channel transmission is complete.
Endpoint 0 IN Transmission Complete Interrupt.
0 = Endpoint 0 IN channel transmission is not complete.
1 = Endpoint 0 IN channel transmission is complete.
Endpoint 3 OUT Reception Complete Interrupt.
0 = Endpoint 3 OUT channel reception is not complete.
1 = Endpoint 3 OUT channel reception is complete.
Endpoint 2 OUT Reception Complete Interrupt.
0 = Endpoint 2 OUT channel reception is not complete.
1 = Endpoint 2 OUT channel reception is complete.
Endpoint 1 OUT Reception Complete Interrupt.
0 = Endpoint 1 OUT channel reception is not complete.
1 = Endpoint 1 OUT channel reception is complete.
Endpoint 0 OUT Reception Complete Interrupt.
0 = Endpoint 0 OUT channel reception is not complete.
1 = Endpoint 0 OUT channel reception is complete.
UDC Configuration Done Interrupt.
EP2I_INT
EP1I_INT
EP0I_INT
EP3O_INT
EP2O_INT
EP1O_INT
EP0O_INT
CFGDN_INT
CFGNEXT_INT
0 = UDC configuration is not complete.
1 = UDC configuration is complete.
Next Configuration Data dword Requested Interrupt.
0 = Next configuration data dword is not requested.
1 = Next configuration data dword is requested.
8-24
Conexant Proprietary and Confidential Information
101306C