欢迎访问ic37.com |
会员登录 免费注册
发布采购

28222-13 参数 Datasheet PDF下载

28222-13图片预览
型号: 28222-13
PDF下载: 下载PDF文件 查看货源
内容描述: ATM发射器/接收器与UTOPIA接口 [ATM Transmitter/Receiver with UTOPIA Interface]
分类和应用: 异步传输模式ATM
文件页数/大小: 161 页 / 1722 K
品牌: CONEXANT [ CONEXANT SYSTEMS, INC ]
 浏览型号28222-13的Datasheet PDF文件第89页浏览型号28222-13的Datasheet PDF文件第90页浏览型号28222-13的Datasheet PDF文件第91页浏览型号28222-13的Datasheet PDF文件第92页浏览型号28222-13的Datasheet PDF文件第94页浏览型号28222-13的Datasheet PDF文件第95页浏览型号28222-13的Datasheet PDF文件第96页浏览型号28222-13的Datasheet PDF文件第97页  
CN8223  
3.0 Registers  
ATM Transmitter/Receiver with UTOPIA Interface  
3.3 Configuration Control Registers  
0x01CONFIG_2 (Configuration Control Register 2)  
The CONFIG_2 register is located at address 0x01 and controls transmit formatting and alarm generation.  
Table 3-4 defines Alarm Controls for the Line Framing/PHY Formats. Table 3-5 defines the control bits for  
STS-1/STS-3c/STM-1. Table 3-6 defines the overhead bits for Line Framing/PHY Formats.  
Field  
Size  
Bit  
15  
Name  
Description  
1
Enable External  
Overhead  
Enables all overhead octets to be inserted externally in STS-1/STS-3c/STM-1 and  
G.832 E3/E4 modes. If this bit is not set, internal generation of overhead octets is  
enabled as described in Section 2.3.  
14  
1
1
3
All-Zeros FEBE  
Inserts an all-0s value in the FEBE field. The all-0s value provides an indication at  
the far end that no BIP-8 errors are being detected. BIP-8 status and error counts  
are not affected. This control bit is active in all modes whether the FEBE field is  
single- or multi-bit.  
13  
All-1s FEBE  
Inserts an all-1s value in the FEBE field of the transmit frame. The all-1s value  
notifies the far end that the FEBE function is inhibited. BIP-8 status and error counts  
are not affected. This control bit is active in all modes whether the FEBE field is  
single- or multi-bit.  
1210  
BIP Error Insert  
Selects the BIP field that will be errored with the TXFEAC_ERRPAT register  
according to the following:  
Bit 12  
Bit 11  
Bit 10  
BIP Field to be Errored  
No errors inserted  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
B1 field (all modes)  
B2 field, bits 23:16 (STS-3c/STM-1 mode only)  
B2 field, bits 15:8 (STS-3c/STM-1 mode only)  
B2 field, bits 7:0 (STS-1/STS-3c/STM-1 modes)  
B3 field (STS-1/STS-3c/STM-1 modes)  
No errors inserted  
B2 field, all 3 octets (STS-3c/STM-1 mode)  
These bits are cleared by the transmitter after the error is inserted in the overhead  
field, and can be read as 0 to verify that error insertion has taken place.  
94  
30  
6
4
Transmit Alarm  
Control  
Controls the generation of alarms for 57-octet PLCPs and internal framers. No  
alarms are transmitted if all bits in this control field are set to 0. Setting any of these  
bits to a 1 causes an alarm to be transmitted according to Table 3-4 and Table 3-5.  
For example, in STS-3c mode, setting bit 4 to a 1 will cause the Line AIS alarm to be  
transmitted.  
Overhead Control  
Selectively disables overhead generation. Standard overhead is generated internally  
if all bits in this control field are set to 0. Overhead sources for all PHY modes are  
given in Table 2-8. When a particular overhead field is set to be disabled, it will be  
filled with 0s. Overhead generation is disabled dependent on mode, according to the  
data in Table 3-6.  
100046C  
Conexant  
3-7  
 复制成功!