4-Level FSK Modem Data Pump  
Page 43 of 50  
MX929B PRELIMINARY INFORMATION  
5.6  
Received Signal Quality Monitor  
In applications where the modem has to monitor a long transmission containing a number of concatenated  
Frames, it is recommended that the controlling software include a function which regularly checks that the  
modem is still receiving a good data signal and triggers a re-acquisition and possibly changes to another  
channel if a problem is encountered. This strategy has been shown to improve the system's overall  
performance in situations where fading, large noise bursts, severe co-channel interference, or loss of the  
received signal for long periods are likely to occur.  
Such a function can be simply implemented by regularly reading the Data Quality Register, which gives a  
measure of the overall quality of the received signal, as well as the current effectiveness of the modem's clock  
extraction and level measurement systems. Experience has shown that if two consecutive DQ readings are  
both less than 50 then it is worth instructing the MX929B to re-acquire the received signal levels and timing  
once it has been established that the received carrier level is satisfactory. Re-acquisition should follow the  
procedure given in Section 5.3.  
The interval between Data Quality readings is not critical, but should be a minimum of 64 symbol times except  
for the first reading made after triggering the AQSC and AQLEV automatic acquisition sequences, which  
should be delayed for about 250 symbol times.  
A suitable algorithm is shown in Figure 27.  
AQSC/AQLEV  
task issued  
Reset timer.  
Set µC variable 'LAST_DQ' to 99  
No  
Note: Times are symbol times.  
Timer > 250 ?  
Read DQ register into  
µC variable 'THIS_DQ'  
No  
No  
'THIS_DQ' < 50 ?  
Yes  
'LAST_DQ' < 50 ?  
Yes  
Copy 'THIS_DQ' to 'LAST DQ'.  
Reset Timer.  
Yes  
No  
Re Acquire  
Timer > 64 ?  
Figure 27: Received Signal Quality Monitor Flowchart  