MX929B PRELIMINARY INFORMATION  
5.3  
5.3.1 Supported Types of Systems  
The MX929B is intended for use in systems where:  
Clock Extraction and Level Measurement Systems  
1. The Symbol Sync pattern is transmitted immediately on start-up of the transmitter, before the first Frame  
Sync pattern (see Figure 23).  
2. A Base Station may remain powered up indefinitely, transmitting concatenated Frames with or without  
intervening Symbol Sync patterns (each Frame starting with the Frame Sync pattern and symbol timing  
being maintained from one Frame to the next).  
3. A receiving modem may be switched onto a channel before the distant transmitter has started up or may  
be switched onto a channel where the transmitting station is already sending concatenated Frames.  
5.3.2 Clock and Level Acquisition Procedures with RF Carrier Detect  
When the receiving modem is enabled or switched onto a channel, it needs to establish the received symbol  
levels, clock timing, and look for a Frame Sync pattern in the incoming signal. This is best done by the  
following procedure:  
1. Ensure that the Control Register's PLLBW bits are set to 'Wide' and the LEVRES bits to 'Level Track'.  
2. Wait until a received carrier has been present for 8 symbol times. This 8-symbol delay gives time for the  
received signal to propagate through the modem's RRC filter. An 'RF received 8 symbol times' qualifying  
function can be included in a radio's carrier detect circuitry to take this into account.  
3. Write a SFS or SFP task to the Command Register with the AQSC and the AQLEV bits set to '1'.  
4. When the modem interrupts to signal that it has recognized a Frame Sync pattern (or completed the SFP  
task) then change the PLLBW bits to 'Medium'.  
Once the receiving modem has achieved level and symbol timing synchronization with a particular channel -  
as evidenced by recognition of a Frame Sync pattern - then subsequent concatenated Frames can be read by  
simply issuing SFS or SFP tasks at appropriate times, keeping the ASQSC and AQLEV bits at zero, and the  
PLLBW and LEVRES bits at their current 'Medium' and 'Level Track' settings, respectively.  
Noise  
Symbol Sync  
Frame Sync  
Rest of Frame  
Rx Signal from  
FM discriminator  
to Modem  
8-Symbol delay  
Set AQSC and AQLEV bits  
to start Acquisition sequences  
Level Measurement and Clock  
Extraction Circuits  
Increasing accuracy and lengthening response times  
Figure 23: Acquisition Sequence Timing  
5.3.3 Clock and Level Acquisition Procedure without RF Carrier Detect  
It is also possible to use the modem in a non-standard system where there is an indeterminate delay between  
the RF transmitter turn on time and the transmission moment of the Symbol Sync pattern, or where a receive  
carrier detect signal is not available to the controlling PC, or where the transmitting terminal can send separate  
unsynchronized Frames. In these cases, each Frame should be preceded by a Symbol Sync pattern, which  
should be extended to about 100 symbols, and the procedure provided in Section 5.3.2.  
©2001 MX-COM, INC.  
www.mxcom.com Tel: 800 638 5577 336 744 5050 Fax: 336 744 5054  
Doc. # 20480171.003  