Analogue Control Interface
FX839
1.7.1 Electrical Performance (continued)
Timing Diagrams
Figure 4: 'C-BUS' Timing
For the following conditions unless otherwise specified:
DV = 3.3V to 5.0V, Tamb = -40°C to +85°C.
DD
Parameter
Notes
Min.
2.0
4.0
-
Typ.
Max.
Units
t
t
t
t
t
t
"CS-Enable to Clock-High"
Last "Clock-High to CS-High"
"CS-High to Reply Output 3-state"
"CS-High" Time between transactions
"Inter-Byte" Time
-
µs
µs
µs
µs
µs
µs
CSE
CSH
HIZ
-
2.0
-
2.0
4.0
2.0
CSOFF
NXT
CK
-
"Clock-Cycle" time
-
Notes: 1. Depending on the command, 1 or 2 bytes of COMMAND DATA are transmitted to the peripheral
MSB (Bit 7) first, LSB (Bit 0) last. REPLY DATA is read from the peripheral MSB (Bit 7) first, LSB
(Bit 0) last.
2. Data is clocked into and out of the peripheral on the rising SERIAL CLOCK edge.
3. Loaded commands are acted upon at the end of each command.
4. To allow for differing µController serial interface formats 'C-BUS' compatible ICs are able to work
with either polarity SERIAL CLOCK pulses.
Consumer Microcircuits Limited
20
1997
D/839/4