Application Information ......  
PLLacq Rx Hold  
PLL Action  
“1”  
X
Acquire: Sets the PLL bandwidth wide enough to allow a lock to the received signal in  
less than 8 zero crossings. The Acquire mode will operate as long as PLLacq is a logic  
“1”.  
“1” to “0”  
“1”  
Medium Bandwidth: The correction applied to the extracted clock is limited to a  
maximum of ±1/16th bit-period for every two received zero-crossings. The PLL operates  
in this mode for a period of about 30 bits immediately following a “1” to “0” transition of the  
PLLacq input, provided that the Rx Hold input is a logic “1”.  
“0”  
“0”  
“1”  
“0”  
Narrow Bandwidth: The correction applied to the extracted clock is limited to a maximum  
of ±1/64th bit-period for every two received zero-crossings. The PLL operates in this  
mode whenever the Rx Hold Input is a logic “1” and PLLacq has been a logic “0” for at  
least 30 bit periods (after Medium Bandwidth operation for instance).  
Hold: The PLL feedback loop is broken, allowing the Rx Clock to freewheel during signal  
fade periods.  
RxDCacq Rx Hold  
Rx Level Measure Action  
“0” to “1”  
X
Clamp: Operates for one bit-time after a “0” to “1” transition of the RxDCacq input. The  
external capacitors are rapidly charged towards a voltage mid-way between the received  
signal input level and VBIAS, with the charge time-constant being of the order of 0.5bit-time.  
“1”  
X
Fast Peak Detect: The voltage detectors act as peak-detectors, one capacitor is used to  
capture the ‘positive’-going signal peaks of the Rx Filter output signal and the other  
capturing the ‘negative’-going peaks. The detectors operate in this mode whenever the  
RxDCacq input is at a logic “1,” except for the initial 1-bit Clamp-mode time.  
“0”  
“0”  
“1”  
“0”  
Averaging Peak Detect: Provides a slower but more accurate measurement of the signal  
peak amplitudes.  
Hold: The capacitor charging circuits are disabled so that the outputs of the voltage  
detectors remain substantially at the last readings (discharging very slowly [time-constant  
approx. 2,000bits] towards VBIAS).  
Table 2 PLL and Rx Level Measurement Operational Modes  
Rx Clock Extraction  
Rx Data Extraction  
Synchronized by a phased locked loop (PLL)  
circuit to zero-crossings of the incoming data, the ‘Rx  
Clock Extraction’ circuitry controls the ‘Rx Clock’  
output. The Rx Clock is also used internally by the  
Data Extraction circuitry. The PLL parameters can be  
varied by the ‘Rx Circuit Control’ inputs PLLacq and Rx  
Hold to operate in one of four PLL modes as described  
in Table 2.  
The ‘Rx Data Extraction’ circuit decides whether  
each received bit is a “1” or “0” by sampling the output  
of the Rx Filter in the middle of each bit-period, and  
comparing the sampled voltage against a threshold  
derived from the ‘Level Measuring’ circuit. This  
threshold is varied on a bit-by-bit basis to compensate  
for intersymbol interference depending on the chosen  
BT. The extracted data is output from the ‘Rx Data’  
pin, and should be sampled externally on the rising  
edge of the ‘Rx Clock.’  
Rx S/N Detection  
The ‘Rx S/N Detector’ system classifies the  
incoming zero-crossings as GOOD or BAD depending  
upon the time when each crossing actually occurs with  
respect to its expected time as determined by the  
Clock Extraction PLL. This information is then  
processed to provide a logic level output at the ‘Rx S/  
N’ pin.  
By monitoring, and averaging, this output it is  
possible to derive a measure of the Signal-to-Noise-  
Ratio and hence the Bit-Error-Rate of the received  
signal.  
7