Evaluation Kit for CMX990  
EV9900A  
2.  
Preliminary Information  
The EV9900A provides a platform for the evaluation of the CMX990. To use the EV9900A, a  
separate micro-controller or PC, for example, is required to program the CMX990 via its parallel  
interface. This controlling device is not included on the EV9900A, however a CML product is  
available to provide the controlling functionality: the EV9902.  
2.1  
Laboratory Equipment  
The following laboratory equipment is needed to use this evaluation kit:  
Dual Power Supply  
Spectrum Analyzer  
RF Attenuator  
RF Signal Generator  
For more detailed design or investigation work the other RF test equipment may be required.  
2.1.1 Power Supply  
The supply input voltage to the PCB, for all circuits except the PA, is 7.2V (5.25V to 7.6V  
acceptable). On board regulators are provided to generate all voltage rails used on the PCB (3V  
and 5V rails are used).  
The supply to the PA is directly connected to the PA: a voltage of 3.6V is recommended.  
The 7.2V supply should be rated at 1A and the 3.6V supply rated at 2A.  
NOTE: Care should be exercised with the supplies as they are not protected for reverse  
polarity. For optimum RF performance, the PA supply is connected directly to the  
RF5110G device so care is required to ensure the RF5110G manufacturer's ratings are not  
exceeded.  
2.2  
Handling Precautions  
Like most evaluation kits, this product is designed for use in office and laboratory environments.  
The following practices will help ensure its proper operation.  
2.2.1 Static Protection  
This product uses low power CMOS circuits that can be damaged by electrostatic discharge.  
Partially damaged circuits can function erroneously, leading to misleading results. Observe ESD  
precautions at all times when handling this product.  
2.2.2 Contents - Unpacking  
Please ensure that you have received all of the items on the separate information sheet  
(EK9900A) and notify CML within 7 working days if the delivery is incomplete.  
2.3  
Approvals  
This product is not approved to any EMC or other regulatory standard. Users are advised  
to observe local statutory requirements, which may apply to this product and the radio  
frequency signals that may emanate from it.  