CS8900A  
Crystal LAN™ ISA Ethernet Controller  
5.7.11 Transmit Frame Length  
this situation is described in the following para-  
graphs.  
The length of the frame transmitted is determined  
by the value written into the TxLength register  
(PacketPage base + 0146h) during the Transmit  
Request. The length of the transmit frame may be  
modified by the configuration of the TxPadDis bit  
(Register 9, TxCMD, Bit D) and the InhibitCRC bit  
(Register 9, TxCMD, Bit C). Table 35 defines how  
these bits affect the length of the transmit frame. In  
addition, it shows which frames the CS8900A will  
send.  
The original IEEE 802.3 specification requires the  
MAC to wait until 4 valid link-pulses are received  
before asserting Link-OK. Any time an invalid  
link-pulse is received, the count is restarted. When  
auto-negotiation occurs, a transmitter sends FLPs  
(auto-negotiation Fast Link Pulses) bursts instead  
of the original IEEE 802.3 NLP (Normal Link  
Pulses).  
If the hub is attempting to auto-negotiate with the  
CS8900A, the CS8900A will never get more than 1  
"valid" link pulse (valid NLP). This is not a prob-  
lem if the CS8900A is already sending link-pulses,  
because when the hub receives NLPs from the  
CS8900A, the hub is required to stop sending FLPs  
and start sending NLPs. The NLP transmitted by  
the hub will put the CS8900A into Link-OK.  
5.8 Full duplex Considerations  
The driver should not bid to transmit a long frame  
(i.e., a frame greater than 118 bytes) if the prior  
transmit frame is still being transmitted. The end of  
the transmission of this prior frame is indicated by  
a TxOK bit being set in the TxEvent register (reg-  
ister 8).  
However, if the CS8900A is in Auto-Switch mode,  
the CS8900A will never send any link-pulses, and  
the hub will never change from sending FLPs to  
sending NLPs.  
5.9 Auto-Negotiation Considerations  
When the CS8900A is connected to an auto negoti-  
ation hub, and if auto-media detection is selected  
(bits 8 and 9 of register 13), then the CS8900A may  
not auto-select the 10BASE-T media. The cause of  
Register 9, TxCMD  
Host specified transmit length at 0146h (in bytes)  
60 < TxLength < 1514 < TxLength < 1518 TxLength > 1518  
TxPad- InhibitCRC 3 < TxLength < 60  
Dis (Bit D)  
(Bit C)  
1514  
0
0
Pad to 60 and add Send frame and add  
Will not send  
Will not send  
Will not send  
Will not send  
CRC  
CRC [Normal Mode]  
0
1
1
0
Pad to 60 and  
send without CRC  
Send frame without  
CRC  
Send frame without  
CRC  
Send without  
pads, and add  
CRC  
Send frame and add  
CRC  
Will not send  
1
1
Send without  
pads and without  
CRC  
Send frame without  
CRC  
Send frame without  
CRC  
Wiill not send  
Notes: 8. If the TxPadDis bit is clear and InhibitCRC is set and the CS8900A is commanded to send a frame of  
length less than 60 bytes, the CS8900A pads.  
9. The CS8900A will not send a frame with TxLength less than 3 bytes.  
Table 35. Transmit Frame Length  