17
A-Series Circuit Breaker - Rocker UL489A – Ordering Scheme
A F 1 B 0 14 450 1 3 1 M T
8
9
10
Mounting/
Barriers
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. Appl. Agency
Rating Approval
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
5
1 SERIES
8 TERMINAL
6
7
7
A
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
9
Screw 10-32 (Bus Type)
& 30° bend
B
F
Screw M5 with upturned lugs
Screw M5 with upturned lugs
& 30° bend
1
2 ACTUATOR
Two Color Visi-Rocker
Push-To-Reset, Visi-Rocker
C
D
F
Indicate ON, vertical legend
Indicate ON, horizontal legend
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
N
O
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
G
H
M
P
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
M6 Threaded Stud
Printed Circuit Board Terminals
Push-In Stud
7
8
9
7
8
G
Single color
J
K
Push-To-Reset , Single color
Q
Vertical legend
Horizontal legend
R
U
Vertical legend
Horizontal legend
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking:
Marking Color
10
10
Visi-Color
White
Black
ON-OFF
Dual
Single Color Visi-Rocker
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
White
White
White
Black
Black
Black
White
n/a
Red
Green
Blue
Yellow
Gray
Orange
Red
Green
Blue
Yellow
Gray
Orange
L
N
Q
S
11
10 MOUNTING / BARRIERS
STANDARD ROCKER BEZEL
Threaded Insert, 2 per pole
6-32 x 0.195 inches
6-32 X 0.195 inches (multi-pole units only)
ISO M3 x 5mm
ISO M3 x 5mm (multi-pole units only)
ROCKERGUARD & PUSH-TO-RESET BEZEL
Threaded Insert, 2 per pole
6-32 x 0.195 inches
BARRIERS
1
no
A
2
yes
no
2
3 POLES
1
2
3
One
B
yes
Two
Three
3
no
C
4
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
yes
no
4 CIRCUIT
B
Series Trip (Current)
D
ISO M3 x 5mm (multi-pole units only)
yes
FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel
8
H
without Rockerguard (single pole units only)
with Rockerguard (single pole units only)
no
no
2
5 AUXILIARY / ALARM SWITCH
7
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
0
1
2
without Aux Switch
FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel
without Rockerguard (single pole units only)
with Rockerguard (single pole units only)
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
8
9
9
J
no
no
6 FREQUENCY & DELAY
11 MAXIMUM APPLICATION RATING
80 DC
11
12
14
16
DC Ultra Short
DC Short
52
54
56
DC, Short, High-inrush
DC, Medium, High-inrush
DC, Long, High-inrush
M
DC Medium
DC Long
12 AGENCY APPROVAL
T
K
J
UL489A Listed
UL489A Listed, VDE Certified
UL489A Listed, TUV Certified
7 CURRENT RATING (AMPERES)
CODE AMPERES
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
Notes:
1
2
Push-To-Reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or
mixed poles, and have one rocker per breaker.
3
4
5
6
7
Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half shells.
30-50A are supplied with extended boat (B-Style) half shells.
VDE Certification available with single pole breakers only. UL489A Listing available with one
and two pole breakers.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps
are only available with Terminal Codes 5, 9, G, H, M and Q.
Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30
amps with UL489A Listing, but is not recommended over 20 amps.
4
635 35.000
Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only TUV or VDE Certified when the washers are used.
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps
with VDE Certification and 50 amps with UL489A Listing.
4
640 40.000
4
645 45.000
4
8
9
650 50.000
Terminal Code Q not available with VDE certification.
10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend.
11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U.
Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes
N & O. Rockerguard available with actuator codes C through K
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com