A-Series Circuit Breaker - Sealed Toggle UL Recognized – Ordering Scheme
A M 1 B 0 10 450 1 0 1 C
8
9
10
Mounting/
Barriers
11
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
9
1 SERIES
A
8 TERMINAL
10
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
E
F
Screw M4 (Bus Type)
Screw M5 with upturned lugs
& 30° bend
1
2 ACTUATOR
G
H
L
M
Q
R
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
0.250 Q.C./ Solder Lug
M6 Threaded Stud
M
Sealed Toggle, one per unit
12
3 POLES
7
8
9
Push-In Stud
1
2
3
One
Screw M4 with upturned lugs
& 30° bend
Screw M4 (Bus Type)
& 30° bend
Printed Circuit Board Terminals
Push-On 0.110 Tab (Q.C.)
Two
Three
T
Screw 10-32 (Bus Type)
& 30° bend
Screw M5 with upturned lugs
Screw M4 with upturned lugs
12
P
S
4 CIRCUIT
2
3
3
3,4
3,4
B
C
A
B
C
D
E
Switch Only (No Coil)
F
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
G
H
3
3
K
9 LEGEND PLATE
No legend plate
0
5
5 AUXILIARY / ALARM SWITCH
5
7
S.P.S.T., 0.093 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
10 MOUNTING / BARRIERS
0
1
2
4
without Aux Switch
MOUNTING STYLE
BARRIERS
no
yes
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.093 Q.C. Term.
(Gold Contacts)
1
Standard Hex Nut
Standard Hex Nut (multipole only)
A
8
9
11 AGENCY APPROVAL
C
I
UL Recognized & CSA Accepted
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
11
DC Ultra Short
12 DC Short
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
Notes:
14 DC Medium
1
Actuator Code M: Handle location as viewed from front of panel:
2 pole - right pole 3 pole - center pole
7
7
7
7
7
7
16 DC Long
42 50/60Hz Short, High-inrush
20 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
44 50/60Hz Medium, High-inrush
2
Switch Only circuits, rated up to 50 amps and 3 poles. Only available when tied to a
protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps,
select Current Code 650.
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for available Dual Coil options, as special catalog number is required. With
Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require
30VA minimum power to trip and are rated for intermittent duty only.
Auxiliary Switch available on Series Trip & Switch Only circuits, limited to 30 amps.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20.
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA
Accepted & TUV Certified to 50 amps.
46 50/60Hz Long, High-inrush
52 DC, Short, High-inrush
3
4
54 DC, Medium, High-inrush
56 DC, Long, High-inrush
5
7 CURRENT RATING (AMPERES)
CODE AMPERES
6
7
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
8
9
UL Recognition and CSA Certification available on one and two pole breakers.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over
30 amps are only available with Terminal Codes 5, 9, B, F, G, H, M and Q.
10 Terminal Code 1: UL Recognition and CSA Certification up to 30 amps, but not
recommended over 20 amps.
11 Terminal Code L : available up to 30A.
12 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to
50 amps, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P
(Printed Circuit Board) are available up to 40 amps with Circuit Codes A, B and C.
8
635 35.000
8
640 40.000
8
645 45.000
8
650 50.000
6
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
CODE AMPERES
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
J06
6 AC
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com