ELECTRICAL SPECIFICATIONS
AV
CC
= +5.0 V, AGND = 0.0 V, Output Load = 1 kΩ and 10 pF, V
IN
= 2.0 Vp-p,Internal Reference, unless otherwise specified.
PARAMETERS
Track Mode Dynamics
Bandwidth (-3 dB)
Single Ended Out
Differential Out
Slew Rate 2.0 Vp-p Output Step
Single Ended Out
Differential Out
7
Input RMS Spectral Noise
Track-to-Hold Switching
Aperture Delay
Aperture Jitter
Pedestal Offset
Hold Mode Dynamics
4
(V
IN
= 1 Vp-p)
Worst Harmonic
5 MHz, 50 MSPS, Single-Ended
Worst Harmonic
5 MHz, 50 MSPS, Differential
Worst Harmonic
25 MHz, 50 MSPS, Single-Ended
Worst Harmonic
25 MHz, 50 MSPS, Differential
Worst Harmonic
50 MHz, 100 MSPS, Single-Ended
Worst Harmonic
50 MHz, 100 MSPS, Differential
Sampling Bandwidth
5
(-3 dB)
V
IN
= 2.0 Vp-p
Hold Noise
6
(RMS)
Droop Rate, V
IN
= +2.5 V
Feedthrough Rejection (50 MHz)
V
IN
= 2 Vp-p
TEST
CONDITIONS
+25
°C
TEST
LEVEL
MIN
SPT9110
TYP
MAX
UNITS
V
V
+25
°C
20 pF Load
20 pF Load
Single Ended
Differential
+25
°C
+25
°C
+25
°C
Full Temperature
220
140
580
800
3.5
13.0
250
<1
±12
±12
MHz
MHz
V/µs
V/µs
nV/
Hz
IV
IV
V
V
V
V
IV
V
nV/
Hz
ps
ps rms
mV
mV
T
A
= +25
°C
T
A
= -40
°C
to +85
°C
T
A
= +25
°C
T
A
= -40
°C
to +85
°C
T
A
= +25
°C
T
A
= -40
°C
to +85
°C
T
A
= +25
°C
T
A
= -40
°C
to +85
°C
T
A
= +25
°C
T
A
= -40
°C
to +85
°C
T
A
= +25
°C
T
A
= -40
°C
to +85
°C
+25
°C
+25
°C
+25
°C
Full Temperature
Full Temperature
IV
V
IV
V
V
V
V
V
IV
V
IV
V
V
V
IV
IV
V
-64
-68
-64
-65
-63
-66
-63
-64
-60
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
MHz
mV/s
mV/µs
mV/µs
dB
-61
-54
-58
-54
-54
-50
400
300 x t
H
±40
±80
-65
-50
4. For hold times longer than 50 ns, the input common mode voltage may affect the hold mode distortion. (This is due to nonlinear
droop that varies with VCM.) For optimal performance, CADEKA recommends that the held output signal be used within 50 ns of the
application of the hold signal.
5. Sampling bandwidth is defined as the -3 dB frequency response of the input sampler to the hold capacitor when operating in the
sampling mode. It is greater than tracking bandwidth because it does not include the bandwidth of the output amplifier.
6. Hold mode noise is proportional to the length of time a signal is held. This value must be combined with the track mode noise to
obtain total noise.
7. Optimized for hold mode performance and low power.
SPT9110
3
11/12/98