The GND pin must be connected to a clean ground point. In  
many cases, this is the analog ground. Avoid connections  
which are too near the grounding point of a microcontroller or  
digital signal processor. If needed, run a ground trace directly  
from the converter to the power-supply entry or battery-  
connection point. The ideal layout includes an analog ground  
plane dedicated to the converter and associated analog  
circuitry.  
+VCC  
100k  
Y+  
PENIRQ  
In the specific case of use with a resistive touch screen, care  
should be taken with the connection between the converter  
and the touch screen. Although resistive touch screens have  
fairly low resistance, the interconnection should be as short  
and robust as possible. Longer connections are a source of  
error, much like the on-resistance of the internal switches.  
Likewise, loose connections can be a source of error when  
the contact resistance changes with flexing or vibrations.  
X+  
Y–  
On  
Y or X drivers on,  
As indicated previously, noise can be a major source of error  
in touch screen applications (for example, applications that  
require a backlit LCD panel). This EMI noise can be coupled  
through the LCD panel to the touch screen and cause  
flickeringof the converted data. Several things can be done  
to reduce this error, such as using a touch screen with a  
bottom-side metal layer connected to ground to shunt the  
majority of noise to ground. Additionally, filtering capacitors,  
from Y+, Y, X+, and Xpins to ground can also help.  
Caution should be observed under these circumstances for  
settling time of the touch screen, especially operating in the  
single-ended mode and at high data rates.  
or TEMP0, TEMP1  
measurements  
activated.  
FIGURE 15. ADS7846 PENIRQ Functional Block Diagram.  
Furthermore, the PENIRQ output is disabled and low during  
the measurement cycle for X-, Y-, and Z-Position. The PENIRQ  
output is disabled and high during the measurement cycle for  
battery monitor, auxiliary input, and chip temperature. If the last  
control byte written to the ADS7846 contains PD0 = 1, the pen-  
interrupt output function is disabled and is not able to detect  
when the screen is touched. In order to re-enable the pen-  
interrupt output function under these circumstances, a control  
byte needs to be written to the ADS7846 with PD0 = 0. If the  
last control byte written to the ADS7846 contains PD0 = 0, the  
pen-interrupt output function is enabled at the end of the  
conversion. The end of the conversion occurs on the falling  
edge of DCLK after bit 1 of the converted data is clocked out  
of the ADS7846.  
PENIRQ OUTPUT  
The pen-interrupt output function is shown in Figure 15. While  
in power-down mode with PD0 = 0, the Ydriver is on and  
connects the Y-plane of the touch screen to GND. The  
PENIRQ output is connected to the X+ input through two  
transmission gates. When the screen is touched, the X+ input  
is pulled to ground through the touch screen. The PENIRQ  
output goes low due to the current path through the touch  
screen to ground, which initiates an interrupt to the processor.  
During the measurement cycle for X-, Y-, and Z-Position, the  
X+ input is disconnected from the external pull-up resistor.  
This is done to eliminate any leakage current from the  
external pull-up resistor through the touch screen, thus caus-  
ing no errors.  
It is recommended that the processor mask the interrupt  
PENIRQ is associated with whenever the processor sends a  
control byte to the ADS7846. This prevents false triggering  
of interrupts when the PENIRQ output is disabled, as in the  
cases discussed in this section.  
ADS7846  
SBAS125H  
17  