SBAS288D − JUNE 2003 − REVISED AUGUST 2004  
SYSOCAL: System Offset Calibration  
Description: Performs a system offset calibration. The Offset Calibration Register (OFC) is updated after this operation.  
DRDY goes high at the beginning of the calibration. It goes low after the calibration completes and settled data is ready.  
Do not send additional commands after issuing this command until DRDY goes low indicating that the calibration is  
complete.  
SYSGCAL: System Gain Calibration  
Description: Performs a system gain calibration. The Full-Scale Calibration Register (FSC) is updated after this operation.  
DRDY goes high at the beginning of the calibration. It goes low after the calibration completes and settled data is ready.  
Do not send additional commands after issuing this command until DRDY goes low indicating that the calibration is  
complete.  
SYNC: Synchronize the A/D Conversion  
Description: This command synchronizes the A/D conversion. To use, first shift in the command. Then shift in the  
WAKEUP command. Synchronization occurs on the first CLKIN rising edge after the first SCLK used to shift in the  
WAKEUP command.  
1111 1100  
(SYNC)  
0000 0000  
(WAKEUP)  
DIN  
•••  
•  
•••  
SCLK  
•• •  
CLKIN  
Synchronization Occurs Here  
Figure 35. SYNC Command Sequence  
STANDBY: Standby Mode / One-Shot Mode  
Description: This command puts the ADS1255/6 into a low-power Standby mode. After issuing the STANDBY command,  
make sure there is no more activity on SCLK while CS is low, as this will interrupt Standby mode. If CS is high, SCLK activity  
is allowed during Standby mode. To exit Standby mode, issue the WAKEUP command. This command can also be used  
to perform single conversions (see One-Shot Mode section) .  
1111 1101  
(STANDBY)  
0000 0000  
(WAKEUP)  
DIN  
SCLK  
Normal Mode  
Standby Mode  
Normal Mode  
Figure 36. STANDBY Command Sequence  
WAKEUP: Complete Synchronization or Exit Standby Mode  
Description: Used in conjunction with the SYNC and STANDBY commands. Two values (all zeros or all ones) are  
available for this command.  
RESET: Reset Registers to Default Values  
Description: Returns all registers except the CLK0 and CLK1 bits in the ADCON register to their default values.  
This command will also stop the Read Continuous mode: in this case, issue the RESET command after DRDY goes low.  