www.ti.com  
SBAS288D − JUNE 2003 − REVISED AUGUST 2004  
DRATE: A/D Data Rate (Address 03h)  
Reset Value = F0h  
BIT 7  
BIT 6  
BIT 5  
BIT 4  
BIT 3  
BIT 2  
BIT 1  
BIT 0  
DR7  
DR6  
DR5  
DR4  
DR3  
DR2  
DR1  
DR0  
The 16 valid Data Rate settings are shown below. Make sure to select a valid setting as the invalid settings may produce  
unpredictable results.  
Bits 7-0 DR[7: 0]: Data Rate Setting(1)  
11110000 = 30,000SPS (default)  
11100000 = 15,000SPS  
11010000 = 7,500SPS  
11000000 = 3,750SPS  
10110000 = 2,000SPS  
10100001 = 1,000SPS  
10010010 = 500SPS  
10000010 = 100SPS  
01110010 = 60SPS  
01100011 = 50SPS  
01010011 = 30SPS  
01000011 = 25SPS  
00110011 = 15SPS  
00100011 = 10SPS  
00010011 = 5SPS  
00000011 = 2.5SPS  
(1)  
for f  
= 7.68MHz. Data rates scale linearly with f .  
CLKIN  
CLKIN  
I/O: GPIO Control Register (Address 04 )  
H
Reset Value = E0h  
BIT 7  
BIT 6  
BIT 5  
BIT 4  
BIT 3  
BIT 2  
BIT 1  
BIT 0  
DIR3  
DIR2  
DIR1  
DIR0  
DIO3  
DIO2  
DIO1  
DIO0  
The states of these bits control the operation of the general-purpose digital I/O pins. The ADS1256 has 4 I/O pins: D3, D2,  
D1, and D0/CLKOUT. The ADS1255 has two digital I/O pins: D1 and D0/CLKOUT. When using an ADS1255, the register  
bits DIR3, DIR2, DIO3, and DIO2 can be read from and written to but have no effect.  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
DIR3, Digital I/O Direction for Digital I/O Pin D3 (used on ADS1256 only)  
0 = D3 is an output  
1 = D3 is an input (default)  
DIR2, Digital I/O Direction for Digital I/O Pin D2 (used on ADS1256 only)  
0 = D2 is an output  
1 = D2 is an input (default)  
DIR1, Digital I/O Direction for Digital I/O Pin D1  
0 = D1 is an output  
1 = D1 is an input (default)  
DIR0, Digital I/O Direction for Digital I/O Pin D0/CLKOUT  
0 = D0/CLKOUT is an output (default)  
1 = D0/CLKOUT is an input  
Bits 3-0 DI0[3:0]: Status of Digital I/O Pins D3, D2, D1, D0/CLKOUT  
Reading these bits will show the state of the corresponding digital I/O pin, whether if the pin is configured as an  
input or output by DIR3-DIR0. When the digital I/O pin is configured as an output by the DIR bit, writing to the  
corresponding DIO bit will set the output state. When the digital I/O pin is configured as an input by the DIR bit,  
writing to the corresponding DIO bit will have no effect. When DO/CLKOUT is configured as an output and  
CLKOUT is enabled (using CLK1, CLK0 bits in the ADCON register), writing to DIO0 will have no effect.  