DF (Data Format) Bit—The DF bit controls the format of  
the output data, either Two’s Complement or Offset Binary,  
as follows:  
SDL (Serial Data Line) Bit—The SDL bit controls which  
pin on the ADS1210/11 will be used as the serial data output  
pin, either SDIO or SDOUT, as follows:  
SDL  
SERIAL DATA OUTPUT PIN  
DF  
FORMAT  
ANALOG INPUT DIGITAL OUTPUT  
0
1
SDIO  
SDOUT  
Default  
0
Twos  
Complement  
+Full-Scale  
Zero  
Full-Scale  
7FFFFFH  
000000H  
800000H  
Default  
1
Offset Binary  
+Full-Scale  
Zero  
Full-scale  
FFFFFFH  
800000H  
000000H  
If SDL is LOW, then SDIO will be used for both input and  
output of serial data—see the Timing section for more  
details on how the SDIO pin transitions between these two  
states. In addition, SDOUT will remain in a tri-state condi-  
tion at all times.  
These two formats are the same for all bits except the most  
significant, which is simply inverted in one format vs the  
other. This bit only applies to the Data Output Register—it  
has no effect on the other registers.  
Important Note: Since the default condition is SDL LOW,  
SDIO has the potential of becoming an output once every  
data output cycle if the ADS1210/11 is in the Master Mode.  
This will occur until the Command Register can be written  
and the SDL bit set HIGH. See the Interfacing section for  
more information.  
U/B (Unipolar) Bit—The U/B bit controls the limits im-  
posed on the output data, as follows:  
U/B  
MODE  
LIMITS  
0
1
Bipolar  
Unipolar  
None  
Default  
DRDY (Data Ready) Bit—The DRDY bit is a read-only bit  
which reflects the state of the ADS1210/11’s DRDY output  
pin, as follows:  
Zero to +Full-Scale only  
The particular mode has no effect on the actual full-scale  
range of the ADS1210/11, data format, or data format vs  
input voltage. In the bipolar mode, the ADS1210/11 oper-  
ates normally. In the unipolar mode, the conversion result is  
limited to positive values only (zero included).  
DRDY  
MEANING  
0
1
Data Ready  
Data Not Ready  
DSYNC (Data Synchronization) Bit—The DSYNC bit is  
a write-only bit which occupies the same location as DRDY.  
When a ‘one’ is written to this location, the effect on the  
ADS1210/11 is the same as if the DSYNC input pin had  
been taken LOW and returned HIGH. That is, the modulator  
count for the current conversion cycle will be reset to zero.  
This bit only controls what is placed in the Data Output  
Register. It has no effect on internal data. When cleared, the  
very next conversion will produce a valid bipolar result.  
BD (Byte Order) Bit—The BD bit controls the order in  
which bytes of data are read, either most significant byte  
first or least significant byte, as follows:  
DSYNC  
MEANING  
BD  
BYTE ACCESS ORDER  
0
1
No Change in Modulator Count  
Modulator Count Reset to Zero  
0
Most Significant  
Default  
to Least Significant Byte  
The DSYNC bit is provided in order to reduce the number of  
interface signals that are needed between the ADS1210/11  
and the main controller. Consult “Making Use of DSYNC”  
in the Serial Interface section for more information.  
1
Least Significant  
to Most Significant Byte  
Note that when BD is clear and a multi-byte read is initiated,  
A3-A0 of the Instruction Register is the address of the most  
significant byte and subsequent bytes reside at higher ad-  
dresses. If BD is set, then A3-A0 is the address of the least  
significant byte and subsequent bytes reside at lower ad-  
dresses. The BD bit only affects read operations; it has no  
effect on write operations.  
MD2-MD0 (Operating Mode) Bits—The MD2-MD0 bits  
initiate or enable the various calibration sequences, as follows:  
MD2  
MD1  
MD0  
OPERATING MODE  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Normal Mode  
Self-Calibration  
MSB (Bit Order) Bit—The MSB bit controls the order in  
which bits within a byte of data are read, either most  
significant bit first or least significant bit, as follows:  
System Offset Calibration  
System Full-Scale Calibration  
Pseudo System Calibration  
Background Calibration  
Sleep  
MSB  
BIT ORDER  
Reserved  
0
1
Most Significant Bit First  
Least Significant Bit First  
Default  
The Normal Mode, Background Calibration Mode, and  
Sleep Mode are permanent modes and the ADS1210/11 will  
remain in these modes indefinitely. All other modes are  
temporary and will revert to Normal Mode once the appro-  
priate actions are complete. See the Calibration and Sleep  
Mode sections for more information.  
The MSB bit only affects read operations; it has no effect on  
write operations.  