Package Characteristics  
Parameter  
Sym.  
Min.  
Typ.**  
Max.  
Units  
Test Conditions  
Fig. Note  
Input-Output Momentary  
Withstand Voltage†  
V
ISO  
3750  
V rms  
RH < 50%, t = 1 min.,  
T = 25°C  
A
3, 8  
Option 020  
HCNW139  
HCNW138  
5000  
3, 9  
Resistance (Input-Output)  
RI-O  
CI-O  
1012  
0.6  
V
I-O = 500 Vdc  
3
3
RH < 45%  
Capacitance (Input-Output)  
pF  
f = 1 MHz  
**All typicals at TA = 25°C, unless otherwise noted.  
†TheInput-OutputMomentaryWithstandVoltageisadielectricvoltageratingthatshouldnotbeinterpretedasaninput-outputcontinuousvoltagerating.  
For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your equipment level safety  
specification or Avago Application Note 1074 entitledOptocoupler Input-Output Endurance Voltage.”  
Notes:  
1. DC CURRENT TRANSFER RATIO (CTR) is defined as the ratio of output collector current, IO, to the forward LED input current, IF, times 100%.  
2. Pin 7 Open.  
3. Device considered a two-terminal device. Pins 1, 2, 3, and 4 shorted together and Pins 5, 6, 7, and 8 shorted together.  
4. Use of a resistor between pin 5 and 7 will decrease gain and delay time. Significant reduction in overall gain can occur when using resistor values  
below 47 k. For more information, please contact your local Avago Components representative.  
5. Common mode transient immunity in a Logic High level is the maximum tolerable (positive) dVCM/dt of the common mode pulse, VCM, to assure  
that the output will remain in a Logic High state (i.e., VO > 2.0 V). Common mode transient immunity in a Logic Low level is the maximum tolerable  
(negative) dVCM/dt of the common mode pulse, V , to assure that the output will remain in a Logic Low state (i.e., VO <0.8 V).  
CM  
6. In applications where dV/dt may exceed 50,000 V/μs (such as static discharge) a series resistor, RCC, should be included to protect the  
detector IC from destructively high surge currents. The recommended value is RCC = 220 .  
7. Use of a 0.1 F bypass capacitor connected between pins 8 and 5 adjacent to the device is recommended.  
8. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage 4500 V rms for 1 second (leakage detection  
current limit, II-O < 5 A). This test is performed before the 100% production test shown in the IEC/EN/DIN EN 60747-5-2 Insulation Related Char-  
acteristics Table, if applicable.  
9. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage > 6000 V rms for 1 second (leakage detection  
current limit, II-O < 5 A). This test is performed before the 100% production test for partial discharge (method b) shown in the IEC/EN/DIN EN  
60747-5-2 Insulation Related Characteristics Table, if applicable.  