欢迎访问ic37.com |
会员登录 免费注册
发布采购

MEGA128CAN 参数 Datasheet PDF下载

MEGA128CAN图片预览
型号: MEGA128CAN
PDF下载: 下载PDF文件 查看货源
内容描述: 微控制器,带有ISP功能的Flash和CAN控制器128K字节 [Microcontroller WITH 128K BYTES OF ISP FLASH AND CAN CONTROLLER]
分类和应用: 微控制器
文件页数/大小: 413 页 / 5507 K
品牌: ATMEL [ ATMEL ]
 浏览型号MEGA128CAN的Datasheet PDF文件第214页浏览型号MEGA128CAN的Datasheet PDF文件第215页浏览型号MEGA128CAN的Datasheet PDF文件第216页浏览型号MEGA128CAN的Datasheet PDF文件第217页浏览型号MEGA128CAN的Datasheet PDF文件第219页浏览型号MEGA128CAN的Datasheet PDF文件第220页浏览型号MEGA128CAN的Datasheet PDF文件第221页浏览型号MEGA128CAN的Datasheet PDF文件第222页  
Master Receiver Mode  
In the Master Receiver Mode, a number of data bytes are received from a slave trans-  
mitter (see Figure 102). In order to enter a Master mode, a START condition must be  
transmitted. The format of the following address packet determines whether Master  
Transmitter or Master Receiver mode is to be entered. If SLA+W is transmitted, MT  
mode is entered, if SLA+R is transmitted, MR mode is entered. All the status codes  
mentioned in this section assume that the prescaler bits are zero or are masked to zero.  
Figure 102. Data Transfer in Master Receiver Mode  
Device 1  
MASTER  
RECEIVER  
Device 2  
Device 3  
SLAVE  
Device n  
........  
TRANSMITTER  
VCC  
R1  
R2  
SDA  
SCL  
A START condition is sent by writing the following value to TWCR:  
TWCR  
TWINT  
TWEA  
TWSTA  
TWSTO  
TWWC  
TWEN  
TWIE  
value  
1
X
1
0
X
1
0
X
TWEN must be written to one to enable the Two-wire Serial Interface, TWSTA must be  
written to one to transmit a START condition and TWINT must be set to clear the TWINT  
flag. The TWI will then test the Two-wire Serial Bus and generate a START condition as  
soon as the bus becomes free. After a START condition has been transmitted, the  
TWINT flag is set by hardware, and the status code in TWSR will be 0x08 (See Table  
90). In order to enter MR mode, SLA+R must be transmitted. This is done by writing  
SLA+R to TWDR. Thereafter the TWINT bit should be cleared (by writing it to one) to  
continue the transfer. This is accomplished by writing the following value to TWCR:  
TWCR  
TWINT  
TWEA  
TWSTA  
TWSTO  
TWWC  
TWEN  
TWIE  
value  
1
X
0
0
X
1
0
X
When SLA+R have been transmitted and an acknowledgment bit has been received,  
TWINT is set again and a number of status codes in TWSR are possible. Possible sta-  
tus codes in Master mode are 0x38, 0x40, or 0x48. The appropriate action to be taken  
for each of these status codes is detailed in Table 101. Received data can be read from  
the TWDR Register when the TWINT flag is set high by hardware. This scheme is  
repeated until the last byte has been received. After the last byte has been received, the  
MR should inform the ST by sending a NACK after the last received data byte. The  
transfer is ended by generating a STOP condition or a repeated START condition. A  
STOP condition is generated by writing the following value to TWCR:  
TWCR  
TWINT  
TWEA  
TWSTA  
TWSTO  
TWWC  
TWEN  
TWIE  
value  
1
X
0
1
X
1
0
X
A REPEATED START condition is generated by writing the following value to TWCR:  
TWCR  
TWINT  
TWEA  
TWSTA  
TWSTO  
TWWC  
TWEN  
TWIE  
value  
1
X
1
0
X
1
0
X
218  
AT90CAN128  
4250E–CAN–12/04  
 复制成功!