AT90CAN128  
Figure 87. Start Bit Sampling  
RxDn  
IDLE  
START  
BIT 0  
Sample  
(U2Xn = 0)  
0
0
1
1
2
3
2
4
5
3
6
7
4
8
9
5
10  
11  
6
12  
13  
7
14  
15  
8
16  
1
1
2
3
2
Sample  
(U2Xn = 1)  
0
When the clock recovery logic detects a high (idle) to low (start) transition on the RxDn  
line, the start bit detection sequence is initiated. Let sample 1 denote the first zero-sam-  
ple as shown in the figure. The clock recovery logic then uses samples 8, 9, and 10 for  
Normal mode, and samples 4, 5, and 6 for Double Speed mode (indicated with sample  
numbers inside boxes on the figure), to decide if a valid start bit is received. If two or  
more of these three samples have logical high levels (the majority wins), the start bit is  
rejected as a noise spike and the Receiver starts looking for the next high to low-transi-  
tion. If however, a valid start bit is detected, the clock recovery logic is synchronized and  
the data recovery can begin. The synchronization process is repeated for each start bit.  
Asynchronous Data Recovery When the receiver clock is synchronized to the start bit, the data recovery can begin.  
The data recovery unit uses a state machine that has 16 states for each bit in Normal  
mode and eight states for each bit in Double Speed mode. Figure 88 shows the sam-  
pling of the data bits and the parity bit. Each of the samples is given a number that is  
equal to the state of the recovery unit.  
Figure 88. Sampling of Data and Parity Bit  
RxDn  
BIT x  
Sample  
(U2Xn = 0)  
1
1
2
3
2
4
5
3
6
7
4
8
9
5
10  
11  
6
12  
13  
7
14  
15  
8
16  
1
1
Sample  
(U2Xn = 1)  
The decision of the logic level of the received bit is taken by doing a majority voting of  
the logic value to the three samples in the center of the received bit. The center samples  
are emphasized on the figure by having the sample number inside boxes. The majority  
voting process is done as follows: If two or all three samples have high levels, the  
received bit is registered to be a logic 1. If two or all three samples have low levels, the  
received bit is registered to be a logic 0. This majority voting process acts as a low pass  
filter for the incoming signal on the RxDn pin. The recovery process is then repeated  
until a complete frame is received. Including the first stop bit. Note that the Receiver only  
uses the first stop bit of a frame.  
185  
4250E–CAN–12/04  