 浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第79页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第80页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第81页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第82页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第84页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第85页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第86页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第87页  
ATmega32(L)  
executed if a compare match in Timer/Counter0 occurs, i.e., when the OCF0 bit is set in  
the Timer/Counter Interrupt Flag Register – TIFR.  
• Bit 0 – TOIE0: Timer/Counter0 Overflow Interrupt Enable  
When the TOIE0 bit is written to one, and the I-bit in the Status Register is set (one), the  
Timer/Counter0 Overflow interrupt is enabled. The corresponding interrupt is executed if  
an overflow in Timer/Counter0 occurs, i.e., when the TOV0 bit is set in the  
Timer/Counter Interrupt Flag Register – TIFR.  
Timer/Counter Interrupt Flag  
Register – TIFR  
Bit  
7
OCF2  
R/W  
0
6
TOV2  
R/W  
0
5
4
OCF1A  
R/W  
0
3
OCF1B  
R/W  
0
2
TOV1  
R/W  
0
1
OCF0  
R/W  
0
0
TOV0  
R/W  
0
ICF1  
R/W  
0
TIFR  
Read/Write  
Initial Value  
• Bit 1 – OCF0: Output Compare Flag 0  
The OCF0 bit is set (one) when a compare match occurs between the Timer/Counter0  
and the data in OCR0 – Output Compare Register0. OCF0 is cleared by hardware when  
executing the corresponding interrupt handling vector. Alternatively, OCF0 is cleared by  
writing a logic one to the flag. When the I-bit in SREG, OCIE0 (Timer/Counter0 Com-  
pare Match Interrupt Enable), and OCF0 are set (one), the Timer/Counter0 Compare  
Match Interrupt is executed.  
• Bit 0 – TOV0: Timer/Counter0 Overflow Flag  
The bit TOV0 is set (one) when an overflow occurs in Timer/Counter0. TOV0 is cleared  
by hardware when executing the corresponding interrupt handling vector. Alternatively,  
TOV0 is cleared by writing a logic one to the flag. When the SREG I-bit, TOIE0  
(Timer/Counter0 Overflow Interrupt Enable), and TOV0 are set (one), the  
Timer/Counter0 Overflow interrupt is executed. In phase correct PWM mode, this bit is  
set when Timer/Counter0 changes counting direction at $00.  