欢迎访问ic37.com |
会员登录 免费注册
发布采购

ATMEGA2560 参数 Datasheet PDF下载

ATMEGA2560图片预览
型号: ATMEGA2560
PDF下载: 下载PDF文件 查看货源
内容描述: 8位微控制器与256K字节的系统内可编程闪存 [8- BIT Microcontroller with 256K Bytes In-System Programmable Flash]
分类和应用: 闪存微控制器
文件页数/大小: 407 页 / 2985 K
品牌: ATMEL [ ATMEL ]
 浏览型号ATMEGA2560的Datasheet PDF文件第238页浏览型号ATMEGA2560的Datasheet PDF文件第239页浏览型号ATMEGA2560的Datasheet PDF文件第240页浏览型号ATMEGA2560的Datasheet PDF文件第241页浏览型号ATMEGA2560的Datasheet PDF文件第243页浏览型号ATMEGA2560的Datasheet PDF文件第244页浏览型号ATMEGA2560的Datasheet PDF文件第245页浏览型号ATMEGA2560的Datasheet PDF文件第246页  
Electrical Interconnection  
As depicted in Figure 91, both bus lines are connected to the positive supply voltage  
through pull-up resistors. The bus drivers of all TWI-compliant devices are open-drain or  
open-collector. This implements a wired-AND function which is essential to the opera-  
tion of the interface. A low level on a TWI bus line is generated when one or more TWI  
devices output a zero. A high level is output when all TWI devices trim-state their out-  
puts, allowing the pull-up resistors to pull the line high. Note that all AVR devices  
connected to the TWI bus must be powered in order to allow any bus operation.  
The number of devices that can be connected to the bus is only limited by the bus  
capacitance limit of 400 pF and the 7-bit slave address space. A detailed specification of  
the electrical characteristics of the TWI is given in “SPI Timing Characteristics” on page  
372. Two different sets of specifications are presented there, one relevant for bus  
speeds below 100 kHz, and one valid for bus speeds up to 400 kHz.  
Data Transfer and Frame  
Format  
Transferring Bits  
Each data bit transferred on the TWI bus is accompanied by a pulse on the clock line.  
The level of the data line must be stable when the clock line is high. The only exception  
to this rule is for generating start and stop conditions.  
Figure 92. Data Validity  
SDA  
SCL  
Data Stable  
Data Stable  
Data Change  
START and STOP Conditions  
The Master initiates and terminates a data transmission. The transmission is initiated  
when the Master issues a START condition on the bus, and it is terminated when the  
Master issues a STOP condition. Between a START and a STOP condition, the bus is  
considered busy, and no other master should try to seize control of the bus. A special  
case occurs when a new START condition is issued between a START and STOP con-  
dition. This is referred to as a REPEATED START condition, and is used when the  
Master wishes to initiate a new transfer without relinquishing control of the bus. After a  
REPEATED START, the bus is considered busy until the next STOP. This is identical to  
the START behavior, and therefore START is used to describe both START and  
REPEATED START for the remainder of this datasheet, unless otherwise noted. As  
depicted below, START and STOP conditions are signalled by changing the level of the  
SDA line when the SCL line is high.  
242  
ATmega640/1280/1281/2560/2561  
2549A–AVR–03/05  
 复制成功!