 浏览型号AT90PWM3B-16SU的Datasheet PDF文件第89页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第90页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第91页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第92页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第94页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第95页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第96页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第97页  
AT90PWM2/3/2B/3B  
14.6.4  
Phase Correct PWM Mode  
The phase correct PWM mode (WGM02:0 = 1 or 5) provides a high resolution phase correct  
PWM waveform generation option. The phase correct PWM mode is based on a dual-slope  
operation. The counter counts repeatedly from BOTTOM to TOP and then from TOP to BOT-  
TOM. TOP is defined as 0xFF when WGM2:0 = 1, and OCR0A when WGM2:0 = 5. In non-  
inverting Compare Output mode, the Output Compare (OC0x) is cleared on the compare match  
between TCNT0 and OCR0x while upcounting, and set on the compare match while downcount-  
ing. In inverting Output Compare mode, the operation is inverted. The dual-slope operation has  
lower maximum operation frequency than single slope operation. However, due to the symmet-  
ric feature of the dual-slope PWM modes, these modes are preferred for motor control  
applications.  
In phase correct PWM mode the counter is incremented until the counter value matches TOP.  
When the counter reaches TOP, it changes the count direction. The TCNT0 value will be equal  
to TOP for one timer clock cycle. The timing diagram for the phase correct PWM mode is shown  
on Figure 14-7. The TCNT0 value is in the timing diagram shown as a histogram for illustrating  
the dual-slope operation. The diagram includes non-inverted and inverted PWM outputs. The  
small horizontal line marks on the TCNT0 slopes represent compare matches between OCR0x  
and TCNT0.  
Figure 14-7. Phase Correct PWM Mode, Timing Diagram  
OCnx Interrupt Flag Set  
OCRnx Update  
TOVn Interrupt Flag Set  
TCNTn  
(COMnx1:0 = 2)  
OCnx  
(COMnx1:0 = 3)  
OCnx  
1
2
3
Period  
The Timer/Counter Overflow Flag (TOV0) is set each time the counter reaches BOTTOM. The  
Interrupt Flag can be used to generate an interrupt each time the counter reaches the BOTTOM  
value.  
In phase correct PWM mode, the compare unit allows generation of PWM waveforms on the  
OC0x pins. Setting the COM0x1:0 bits to two will produce a non-inverted PWM. An inverted  
PWM output can be generated by setting the COM0x1:0 to three: Setting the COM0A0 bits to  
one allows the OC0A pin to toggle on Compare Matches if the WGM02 bit is set. This option is  
not available for the OC0B pin (see Table 14-7 on page 97). The actual OC0x value will only be  
visible on the port pin if the data direction for the port pin is set as output. The PWM waveform is  
generated by clearing (or setting) the OC0x Register at the compare match between OCR0x and  
TCNT0 when the counter increments, and setting (or clearing) the OC0x Register at compare  
93  