欢迎访问ic37.com |
会员登录 免费注册
发布采购

AT90PWM3B-16SU 参数 Datasheet PDF下载

AT90PWM3B-16SU图片预览
型号: AT90PWM3B-16SU
PDF下载: 下载PDF文件 查看货源
内容描述: 8位微控制器具有8K字节的系统内可编程闪存 [8-bit Microcontroller with 8K Bytes In-System Programmable Flash]
分类和应用: 闪存微控制器
文件页数/大小: 361 页 / 6022 K
品牌: ATMEL [ ATMEL ]
 浏览型号AT90PWM3B-16SU的Datasheet PDF文件第82页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第83页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第84页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第85页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第87页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第88页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第89页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第90页  
The definitions in Table 14-1 are also used extensively throughout the document.  
Table 14-1. Definitions  
BOTTOM  
MAX  
The counter reaches the BOTTOM when it becomes 0x00.  
The counter reaches its MAXimum when it becomes 0xFF (decimal 255).  
TOP  
The counter reaches the TOP when it becomes equal to the highest value in the  
count sequence. The TOP value can be assigned to be the fixed value 0xFF  
(MAX) or the value stored in the OCR0A Register. The assignment is depen-  
dent on the mode of operation.  
14.1.2  
Registers  
The Timer/Counter (TCNT0) and Output Compare Registers (OCR0A and OCR0B) are 8-bit  
registers. Interrupt request (abbreviated to Int.Req. in the figure) signals are all visible in the  
Timer Interrupt Flag Register (TIFR0). All interrupts are individually masked with the Timer Inter-  
rupt Mask Register (TIMSK0). TIFR0 and TIMSK0 are not shown in the figure.  
The Timer/Counter can be clocked internally, via the prescaler, or by an external clock source on  
the T0 pin. The Clock Select logic block controls which clock source and edge the Timer/Counter  
uses to increment (or decrement) its value. The Timer/Counter is inactive when no clock source  
is selected. The output from the Clock Select logic is referred to as the timer clock (clkT0).  
The double buffered Output Compare Registers (OCR0A and OCR0B) are compared with the  
Timer/Counter value at all times. The result of the compare can be used by the Waveform Gen-  
erator to generate a PWM or variable frequency output on the Output Compare pins (OC0A and  
OC0B). See “Using the Output Compare Unit” on page 112. for details. The compare match  
event will also set the Compare Flag (OCF0A or OCF0B) which can be used to generate an Out-  
put Compare interrupt request.  
14.2 Timer/Counter Clock Sources  
The Timer/Counter can be clocked by an internal or an external clock source. The clock source  
is selected by the Clock Select logic which is controlled by the Clock Select (CS02:0) bits  
located in the Timer/Counter Control Register (TCCR0B). For details on clock sources and pres-  
caler, see “Timer/Counter0 and Timer/Counter1 Prescalers” on page 82.  
14.3 Counter Unit  
The main part of the 8-bit Timer/Counter is the programmable bi-directional counter unit. Figure  
14-2 shows a block diagram of the counter and its surroundings.  
Figure 14-2. Counter Unit Block Diagram  
TOVn  
(Int.Req.)  
DATA BUS  
Clock Select  
count  
clear  
Edge  
Detector  
Tn  
clkTn  
TCNTn  
Control Logic  
direction  
( From Prescaler )  
bottom  
top  
Signal description (internal signals):  
86  
AT90PWM2/3/2B/3B  
4317J–AVR–08/10  
 复制成功!