AT89S52  
Figure 10-1. Timer in Capture Mode  
÷12  
OSC  
C/T2 = 0  
C/T2 = 1  
TH2  
TL2  
TF2  
OVERFLOW  
CONTROL  
TR2  
CAPTURE  
T2 PIN  
RCAP2H RCAP2L  
EXF2  
TRANSITION  
DETECTOR  
TIMER 2  
INTERRUPT  
T2EX PIN  
CONTROL  
EXEN2  
Table 10-2. T2MOD – Timer 2 Mode Control Register  
T2MOD Address = 0C9H  
Reset Value = XXXX XX00B  
Not Bit Addressable  
7
6
5
4
3
2
T2OE  
1
DCEN  
0
Bit  
Symbol  
Function  
Not implemented, reserved for future  
Timer 2 Output Enable bit  
T2OE  
DCEN  
When set, this bit allows Timer 2 to be configured as an up/down counter  
Figure 10-2 shows Timer 2 automatically counting up when DCEN = 0. In this mode, two options  
are selected by bit EXEN2 in T2CON. If EXEN2 = 0, Timer 2 counts up to 0FFFFH and then sets  
the TF2 bit upon overflow. The overflow also causes the timer registers to be reloaded with the  
16-bit value in RCAP2H and RCAP2L. The values in Timer in Capture ModeRCAP2H and  
RCAP2L are preset by software. If EXEN2 = 1, a 16-bit reload can be triggered either by an  
overflow or by a 1-to-0 transition at external input T2EX. This transition also sets the EXF2 bit.  
Both the TF2 and EXF2 bits can generate an interrupt if enabled.  
Setting the DCEN bit enables Timer 2 to count up or down, as shown in Figure 10-2. In this  
mode, the T2EX pin controls the direction of the count. A logic 1 at T2EX makes Timer 2 count  
up. The timer will overflow at 0FFFFH and set the TF2 bit. This overflow also causes the 16-bit  
value in RCAP2H and RCAP2L to be reloaded into the timer registers, TH2 and TL2,  
respectively.  
A logic 0 at T2EX makes Timer 2 count down. The timer underflows when TH2 and TL2 equal  
the values stored in RCAP2H and RCAP2L. The underflow sets the TF2 bit and causes 0FFFFH  
to be reloaded into the timer registers.  
The EXF2 bit toggles whenever Timer 2 overflows or underflows and can be used as a 17th bit  
of resolution. In this operating mode, EXF2 does not flag an interrupt.  
13  
1919D–MICRO–6/08  